Meta Data

(Update 26-Sep-2020 UTC)

General information on the meta-data file
DATA_TYPE none
FORMAT_VERSION 3.1
HANDBOOK_VERSION 1.2
DATE_CREATION 2015-06-18 21:26:16
DATE_UPDATE 2015-06-18 21:26:16
Float characteristics
PLATFORM_NUMBER 2900585
PTT 060410
TRANS_SYSTEM ARGOS
TRAN_SYSTEM_ID 03119
TRANS_FREQUENCY 401652000
POSITIONING_SYSTEM ARGOS
PLATFORM_FAMILY FLOAT
PLATFORM_TYPE PROVOR
PLATFORM_MAKER MARTEC
FIRMWARE_VERSION n/a
MANUAL_VERSION 010805
FLOAT_SERIAL_NO 05MT-S3-0014
STANDARD_FORMAT_ID 101001
DAC_FORMAT_ID P5
WMO_INST_TYPE 841
PROJECT_NAME Routine-JMA
DATA_CENTRE JM
PI_NAME JMA
ANOMALY none
BATTERY_TYPE Lithium
BATTERY_PACKS n/a
CONTROLLER_BOARD_TYPE_PRIMARY PROVOR_CTS3
CONTROLLER_BOARD_TYPE_SECONDARY none
CONTROLLER_BOARD_SERIAL_NO_PRIMARY n/a
CONTROLLER_BOARD_SERIAL_NO_SECONDARY none
SPECIAL_FEATURES none
FLOAT_OWNER n/a
OPERATING_INSTITUTION none
CUSTOMISATION none
Float deployment and mission information
LAUNCH_DATE 2006-12-25 05:11:43
LAUNCH_LATITUDE 30.003
LAUNCH_LONGITUDE 134.599
LAUNCH_QC 1
START_DATE 2006-12-25 05:11:43
START_DATE_QC 1
STARTUP_DATE 2006-12-25 05:11:43
STARTUP_DATE_QC none
DEPLOYMENT_PLATFORM Chofumaru
DEPLOYMENT_CRUISE_ID NC05-09
DEPLOYMENT_REFERENCE_STATION_ID NC-6338
END_MISSION_DATE 2006-12-25 05:11:43
END_MISSION_STATUS T
Sensor information
SENSOR CTD_PRES
SENSOR_MAKER DRUCK
SENSOR_MODEL DRUCK
SENSOR_SERIAL_NO 7142
SENSOR CTD_TEMP
SENSOR_MAKER SBE
SENSOR_MODEL SBE41
SENSOR_SERIAL_NO 1055
SENSOR CTD_CNDC
SENSOR_MAKER SBE
SENSOR_MODEL SBE41
SENSOR_SERIAL_NO 1055
Float parameter information
PARAMETER PRES
PARAMETER_SEMSOR CTD_PRES
PARAMETER_UNITS decibar
PARAMETER_ACCURACY 2.4
PARAMETER_RESOLUTION 0.1
PARAMETER PSAL
PARAMETER_SEMSOR CTD_CNDC
PARAMETER_UNITS psu
PARAMETER_ACCURACY 0.005
PARAMETER_RESOLUTION 0.001
PARAMETER TEMP
PARAMETER_SEMSOR CTD_TEMP
PARAMETER_UNITS degree_Celsius
PARAMETER_ACCURACY 0.002
PARAMETER_RESOLUTION 0.001
Float calibration information
PREDEPLOYMENT_CALIB_EQUATION pressure (psia) = pa0 + pa1*n + pa2*n^2 where n= (pressure output -PTCA0-PTCA1*t-PTCA2*t^2)*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2) and t=PTHA0 + PTHA1*y + PTHA2*y^2 where y=temperature output
PREDEPLOYMENT_CALIB_COEFFICIENT PA0=2.984823e-01 PA1=1.384945e-01 PA2=-3.553526e-08 PTHA0=-7.333420e+01 PTHA1=4.995716e-02 PTHA2=-1.752483e-07 PTCA0=-8.743248e+01 PTCA1=1.259783e-01 PTCA2=-1.406104e-03 PTCB0=2.486450e+01 PTCB1=-1.000000e-04 PTCB2=0.000000e+00
PREDEPLOYMENT_CALIB_COMMENT calibrated at 2005/02/11
PREDEPLOYMENT_CALIB_EQUATION PSS 1978:C(35,15,0)=4.2914 Siemens/meter, Conductivity = (g + hf^2 + if^3 + jf^4)/(1+CTcor t + CPcor p) where f= output * sqrt(1.0 + WBOTC * t )/1000.
PREDEPLOYMENT_CALIB_COEFFICIENT g=-1.022520e+00 h=1.536502e-01 i=-1.314576e-04 j=3.318350e-05 CPcor=-9.570001e-08 CTcor=3.250000e-06 WBOTC=-4.882891e-05
PREDEPLOYMENT_CALIB_COMMENT calibrated at 2005/02/13
PREDEPLOYMENT_CALIB_EQUATION Temperature ITS-90 = 1/{a0 + a1[ln(n)] + a2[ln^2(n)] + a3[ln^3(n)]} -273.15
PREDEPLOYMENT_CALIB_COEFFICIENT a0=9.101113e-08 a1=2.780319e-04 a2=-2.444105e-06 a3=1.595914e-07
PREDEPLOYMENT_CALIB_COMMENT calibrated at 2005/02/13
Configuration parameters
CONFIG_AscentTime_hours 6.173
CONFIG_CycleTime_hours 120
CONFIG_Direction_NUMBER 1
CONFIG_FloatReferenceDay_FloatDay 2
CONFIG_MissionPreludeTime_hours 0
CONFIG_ParkPressure_dbar 1000
CONFIG_ParkTime_hours 90.716
CONFIG_ProfilePressure_dbar 2000
CONFIG_TransmissionRepetitionPeriod_seconds 45
CONFIG_TransmissionMinTime_hours 12
CONFIG_MISSION_NUMBER 0
CONFIG_AscentTime_hours 6.173
CONFIG_CycleTime_hours 120
CONFIG_Direction_NUMBER 1
CONFIG_FloatReferenceDay_FloatDay 2
CONFIG_MissionPreludeTime_hours 0
CONFIG_ParkPressure_dbar 1000
CONFIG_ParkTime_hours 90.716
CONFIG_ProfilePressure_dbar 2000
CONFIG_TransmissionRepetitionPeriod_seconds 45
CONFIG_TransmissionMinTime_hours 12
CONFIG_MISSION_COMMENT none