(Update 18-Jan-2021 UTC)
General information on the meta-data file | |
---|---|
DATA_TYPE | none |
FORMAT_VERSION | 3.1 |
HANDBOOK_VERSION | 1.2 |
DATE_CREATION | 2015-06-12 16:05:20 |
DATE_UPDATE | 2015-06-12 16:05:20 |
Float characteristics | |
PLATFORM_NUMBER | 2900657 |
PTT | 067027 |
TRANS_SYSTEM | ARGOS |
TRAN_SYSTEM_ID | 03119 |
TRANS_FREQUENCY | 401653000 |
POSITIONING_SYSTEM | ARGOS |
PLATFORM_FAMILY | FLOAT |
PLATFORM_TYPE | APEX |
PLATFORM_MAKER | WRC |
FIRMWARE_VERSION | 070306 |
MANUAL_VERSION | 080106 |
FLOAT_SERIAL_NO | 2975 |
STANDARD_FORMAT_ID | 001043 |
DAC_FORMAT_ID | A9 |
WMO_INST_TYPE | 846 |
PROJECT_NAME | Routine-JMA |
DATA_CENTRE | JM |
PI_NAME | JMA |
ANOMALY | none |
BATTERY_TYPE | Alkaline |
BATTERY_PACKS | n/a |
CONTROLLER_BOARD_TYPE_PRIMARY | APF8 |
CONTROLLER_BOARD_TYPE_SECONDARY | none |
CONTROLLER_BOARD_SERIAL_NO_PRIMARY | 3137 011 045 |
CONTROLLER_BOARD_SERIAL_NO_SECONDARY | none |
SPECIAL_FEATURES | none |
FLOAT_OWNER | n/a |
OPERATING_INSTITUTION | none |
CUSTOMISATION | none |
Float deployment and mission information | |
LAUNCH_DATE | 2009-01-24 03:09:18 |
LAUNCH_LATITUDE | 31.013 |
LAUNCH_LONGITUDE | 147.012 |
LAUNCH_QC | 1 |
START_DATE | 2009-01-24 03:09:18 |
START_DATE_QC | 1 |
STARTUP_DATE | 2009-01-24 03:09:18 |
STARTUP_DATE_QC | none |
DEPLOYMENT_PLATFORM | Kofumaru |
DEPLOYMENT_CRUISE_ID | KH06-10 |
DEPLOYMENT_REFERENCE_STATION_ID | KH-1806 |
END_MISSION_DATE | 2009-01-24 03:09:18 |
END_MISSION_STATUS | T |
Sensor information | |
SENSOR | CTD_PRES |
SENSOR_MAKER | DRUCK |
SENSOR_MODEL | DRUCK |
SENSOR_SERIAL_NO | 2328590 |
SENSOR | CTD_TEMP |
SENSOR_MAKER | SBE |
SENSOR_MODEL | SBE41 |
SENSOR_SERIAL_NO | 3053 |
SENSOR | CTD_CNDC |
SENSOR_MAKER | SBE |
SENSOR_MODEL | SBE41 |
SENSOR_SERIAL_NO | 3053 |
Float parameter information | |
PARAMETER | PRES |
PARAMETER_SEMSOR | CTD_PRES |
PARAMETER_UNITS | decibar |
PARAMETER_ACCURACY | 2.4 |
PARAMETER_RESOLUTION | 0.1 |
PARAMETER | PSAL |
PARAMETER_SEMSOR | CTD_CNDC |
PARAMETER_UNITS | psu |
PARAMETER_ACCURACY | 0.005 |
PARAMETER_RESOLUTION | 0.001 |
PARAMETER | TEMP |
PARAMETER_SEMSOR | CTD_TEMP |
PARAMETER_UNITS | degree_Celsius |
PARAMETER_ACCURACY | 0.002 |
PARAMETER_RESOLUTION | 0.001 |
Float calibration information | |
PREDEPLOYMENT_CALIB_EQUATION | pressure (psia) = pa0 + pa1*n + pa2*n^2 where n= (pressure output -PTCA0-PTCA1*t-PTCA2*t^2)*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2) and t=PTHA0-PTHA1*y + PTHA2*y^2 where y=temperature output |
PREDEPLOYMENT_CALIB_COEFFICIENT | PA0=1.002530e+00 PA1=1.377883e-01 PA2=-3.754831e-08 PTCA0=-6.364618e+00 PTCA1=2.065236e-01 PTCA2=6.542968e-03 PTCB0=2.608113e+01 PTCB1=-3.575000e-03 PTCB2=0.000000e+00 PTHA0=-5.329354e+01 PTHA1=5.179093e-02 PTHA2=7.263014e-07 |
PREDEPLOYMENT_CALIB_COMMENT | calibrated at 2006/06/19 |
PREDEPLOYMENT_CALIB_EQUATION | PSS 1978:C(35,15,0)=4.2914 Siemens/meter, Conductivity = (g + hf^2 + if^3 + jf^4)/(1+CTcor t + CPcor p) where f= output * sqrt(1.0 + WBOTC * t )/1000. |
PREDEPLOYMENT_CALIB_COEFFICIENT | g=-1.052092e+00 h=1.732639e-01 i=-3.193291e-04 j=5.371572e-05 CPcor=-9.570000e-08 CTcor=3.250000e-06 WBOTC=-4.052158e-07 |
PREDEPLOYMENT_CALIB_COMMENT | calibrated at 2006/06/27 |
PREDEPLOYMENT_CALIB_EQUATION | Temperature ITS-90 = 1/{a0 + a1[ln(n)] + a2[ln^2(n)] + a3[ln^3(n)]} -273.15 |
PREDEPLOYMENT_CALIB_COEFFICIENT | a0=-5.294612e-05 a1=2.850453e-04 a2=-3.054209e-06 a3=1.758365e-07 |
PREDEPLOYMENT_CALIB_COMMENT | calibrated at 2006/06/27 |
Configuration parameters | |
CONFIG_AscentTime_hours | 6.173 |
CONFIG_CycleTime_hours | 120 |
CONFIG_Direction_NUMBER | 1 |
CONFIG_DownTime_hours | 102 |
CONFIG_MissionPreludeTime_hours | 6 |
CONFIG_ParkPressure_dbar | 1000 |
CONFIG_ParkTime_hours | 95.827 |
CONFIG_ProfilePressure_dbar | 2000 |
CONFIG_TransmissionRepetitionPeriod_seconds | 44 |
CONFIG_UpTime_hours | 18 |
CONFIG_MISSION_NUMBER | 0 |
CONFIG_AscentTime_hours | 6.173 |
CONFIG_CycleTime_hours | 120 |
CONFIG_Direction_NUMBER | 1 |
CONFIG_DownTime_hours | 102 |
CONFIG_MissionPreludeTime_hours | 6 |
CONFIG_ParkPressure_dbar | 1000 |
CONFIG_ParkTime_hours | 95.827 |
CONFIG_ProfilePressure_dbar | 2000 |
CONFIG_TransmissionRepetitionPeriod_seconds | 44 |
CONFIG_UpTime_hours | 18 |
CONFIG_MISSION_COMMENT | none |