Meta Data

(Update 23-Sep-2020 UTC)

General information on the meta-data file
DATA_TYPE none
FORMAT_VERSION 3.1
HANDBOOK_VERSION 1.2
DATE_CREATION 2016-11-29 13:25:08
DATE_UPDATE 2016-11-29 13:25:08
Float characteristics
PLATFORM_NUMBER 2901053
PTT 97909
TRANS_SYSTEM ARGOS
TRAN_SYSTEM_ID 02147
TRANS_FREQUENCY 401646000
POSITIONING_SYSTEM ARGOS
PLATFORM_FAMILY FLOAT
PLATFORM_TYPE PROVOR
PLATFORM_MAKER NKE
FIRMWARE_VERSION 5815A03
MANUAL_VERSION 16/03/10 rev.4
FLOAT_SERIAL_NO 09014
STANDARD_FORMAT_ID 101001
DAC_FORMAT_ID P7
WMO_INST_TYPE 841
PROJECT_NAME J-ARGO
DATA_CENTRE JA
PI_NAME JAMSTEC
ANOMALY none
BATTERY_TYPE Alkaline
BATTERY_PACKS none
CONTROLLER_BOARD_TYPE_PRIMARY n/a
CONTROLLER_BOARD_TYPE_SECONDARY none
CONTROLLER_BOARD_SERIAL_NO_PRIMARY 5406
CONTROLLER_BOARD_SERIAL_NO_SECONDARY none
SPECIAL_FEATURES none
FLOAT_OWNER JAMSTEC
OPERATING_INSTITUTION JAMSTEC
CUSTOMISATION none
Float deployment and mission information
LAUNCH_DATE 2011-10-01 06:37:41
LAUNCH_LATITUDE 37.0053
LAUNCH_LONGITUDE 146.0686
LAUNCH_QC 1
START_DATE 2011-10-01 06:37:41
START_DATE_QC 1
STARTUP_DATE 2011-10-01 06:37:41
STARTUP_DATE_QC 1
DEPLOYMENT_PLATFORM Mirai
DEPLOYMENT_CRUISE_ID MR11-03
DEPLOYMENT_REFERENCE_STATION_ID 37N
END_MISSION_DATE 2011-10-01 06:37:41
END_MISSION_STATUS T
Sensor information
SENSOR CTD_PRES
SENSOR_MAKER KISTLER
SENSOR_MODEL KISTLER
SENSOR_SERIAL_NO 2074739
SENSOR CTD_TEMP
SENSOR_MAKER SBE
SENSOR_MODEL SBE41CP_V2
SENSOR_SERIAL_NO 2694
SENSOR CTD_CNDC
SENSOR_MAKER SBE
SENSOR_MODEL SBE41CP_V2
SENSOR_SERIAL_NO 2694
Float parameter information
PARAMETER PRES
PARAMETER_SEMSOR CTD_PRES
PARAMETER_UNITS decibar
PARAMETER_ACCURACY 2.4
PARAMETER_RESOLUTION 0.1
PARAMETER PSAL
PARAMETER_SEMSOR CTD_CNDC
PARAMETER_UNITS psu
PARAMETER_ACCURACY 0.005
PARAMETER_RESOLUTION 0.001
PARAMETER TEMP
PARAMETER_SEMSOR CTD_TEMP
PARAMETER_UNITS degree_Celsius
PARAMETER_ACCURACY 0.002
PARAMETER_RESOLUTION 0.001
Float calibration information
PREDEPLOYMENT_CALIB_EQUATION y = thermistor output; t = PTHA0 + PTHA1 * y + PTHA2 * y^2; x = pressure output - PTCA0 - PTCA1 * t - PTCA2 * t^2; n = x * PTCB0 / (PTCB0 + PTCB1 * t + PTCB2 * t^2); pressure (psia) = PA0 + PA1 * n + PA2 * n^2;
PREDEPLOYMENT_CALIB_COEFFICIENT PA0=-1.712799e+00, PA1=1.372577e-01, PA2=1.475761e-08, PTHA0=-9.590387e+01, PTHA1=4.075721e-02, PTHA2=8.884319e-07, PTCA0=-1.344621e+02, PTCA1=-1.165293e+00, PTCA2=2.711845e-02, PTCB0=1.017883e+02, PTCB1=-7.163613e-03, PTCB2=.000000e+00
PREDEPLOYMENT_CALIB_COMMENT Calibrated on 12/Nov/2010
PREDEPLOYMENT_CALIB_EQUATION f = INST FREQ * sqrt(1.0 + WBOTC * t) / 1000.0; Conductivity = (g + h * f^2+ i * f^3 + j * f^4) / (1 + d * t + e * p) Siemens / meter; t = temperature[degree C]; p = pressure[decibars]; d = CTcor; e = CPcor;
PREDEPLOYMENT_CALIB_COEFFICIENT g=-1.004081e+00, h=1.413876e-01, i=-4.215056e-04, j=4.973445e-05, CPcor=-9.570001e-08, CTcor=3.250000e-06, WBOTC=1.247270e-07
PREDEPLOYMENT_CALIB_COMMENT Calibrated on 30/Nov/2010
PREDEPLOYMENT_CALIB_EQUATION Temperature ITS-90 = 1/{a0 + a1[ln(n)] + a2[ln^2(n)] + a3[ln^3(n)]} - 273.15 (degree C); n = instrument output;
PREDEPLOYMENT_CALIB_COEFFICIENT a0=7.790188e-05, a1=2.661673e-04, a2=-1.790905e-06, a3=1.341666e-07
PREDEPLOYMENT_CALIB_COMMENT Calibrated on 30/Nov/2010
Configuration parameters
CONFIG_CycleTime_hours 120
CONFIG_ParkPressure_dbar 1000
CONFIG_ProfilePressure_dbar 2000
CONFIG_Direction_NUMBER 1
CONFIG_TransmissionRepetitionPeriod_seconds 30
CONFIG_TransmissionMinTime_hours 11
CONFIG_AscentTime_hours 6.173
CONFIG_ParkTime_hours 91.716
CONFIG_ParkSamplingPeriod_hours 72
CONFIG_SurfaceTime_HH 22
CONFIG_DelayBeforeMissionStart_minutes 0
CONFIG_FloatReferenceDay_FloatDay 2
CONFIG_MaxCycles_NUMBER 300
CONFIG_GroundingMode_LOGICAL 0
CONFIG_TelemetryRetransmission_COUNT 25
CONFIG_CTDPumpStopPressure_dbar 5
CONFIG_MISSION_NUMBER 0
CONFIG_CycleTime_hours 120
CONFIG_ParkPressure_dbar 1000
CONFIG_ProfilePressure_dbar 2000
CONFIG_Direction_NUMBER 1
CONFIG_TransmissionRepetitionPeriod_seconds 30
CONFIG_TransmissionMinTime_hours 11
CONFIG_AscentTime_hours 6.173
CONFIG_ParkTime_hours 91.716
CONFIG_ParkSamplingPeriod_hours 72
CONFIG_SurfaceTime_HH 22
CONFIG_DelayBeforeMissionStart_minutes 0
CONFIG_FloatReferenceDay_FloatDay 2
CONFIG_MaxCycles_NUMBER 300
CONFIG_GroundingMode_LOGICAL 0
CONFIG_TelemetryRetransmission_COUNT 25
CONFIG_CTDPumpStopPressure_dbar 5
CONFIG_MISSION_COMMENT none