Meta Data

(Update 23-Sep-2020 UTC)

General information on the meta-data file
DATA_TYPE none
FORMAT_VERSION 3.1
HANDBOOK_VERSION 1.2
DATE_CREATION 2019-08-26 07:15:16
DATE_UPDATE 2019-08-26 07:15:16
Float characteristics
PLATFORM_NUMBER 2902374
PTT 120220
TRANS_SYSTEM ARGOS
TRAN_SYSTEM_ID 03119
TRANS_FREQUENCY 401645030
POSITIONING_SYSTEM ARGOS
PLATFORM_FAMILY FLOAT
PLATFORM_TYPE APEX
PLATFORM_MAKER TWR
FIRMWARE_VERSION 071412
MANUAL_VERSION 011613
FLOAT_SERIAL_NO 6325
STANDARD_FORMAT_ID n/a
DAC_FORMAT_ID A22
WMO_INST_TYPE 846
PROJECT_NAME Routine-JMA
DATA_CENTRE JA
PI_NAME JMA
ANOMALY none
BATTERY_TYPE Alkaline
BATTERY_PACKS n/a
CONTROLLER_BOARD_TYPE_PRIMARY APF9A
CONTROLLER_BOARD_TYPE_SECONDARY none
CONTROLLER_BOARD_SERIAL_NO_PRIMARY 8422
CONTROLLER_BOARD_SERIAL_NO_SECONDARY none
SPECIAL_FEATURES none
FLOAT_OWNER n/a
OPERATING_INSTITUTION none
CUSTOMISATION none
Float deployment and mission information
LAUNCH_DATE 2013-10-19 19:52:02
LAUNCH_LATITUDE 40.341
LAUNCH_LONGITUDE 147.398
LAUNCH_QC 1
START_DATE 2013-10-19 19:52:02
START_DATE_QC 1
STARTUP_DATE 2013-10-19 19:52:02
STARTUP_DATE_QC none
DEPLOYMENT_PLATFORM Ryofumaru
DEPLOYMENT_CRUISE_ID RF12-08
DEPLOYMENT_REFERENCE_STATION_ID RF-4555
END_MISSION_DATE 2013-10-19 19:52:02
END_MISSION_STATUS T
Sensor information
SENSOR CTD_PRES
SENSOR_MAKER DRUCK
SENSOR_MODEL DRUCK
SENSOR_SERIAL_NO 3459034
SENSOR CTD_TEMP
SENSOR_MAKER SBE
SENSOR_MODEL SBE41
SENSOR_SERIAL_NO 5787
SENSOR CTD_CNDC
SENSOR_MAKER SBE
SENSOR_MODEL SBE41
SENSOR_SERIAL_NO 5787
Float parameter information
PARAMETER PRES
PARAMETER_SEMSOR CTD_PRES
PARAMETER_UNITS decibar
PARAMETER_ACCURACY 2.4
PARAMETER_RESOLUTION 0.1
PARAMETER PSAL
PARAMETER_SEMSOR CTD_CNDC
PARAMETER_UNITS psu
PARAMETER_ACCURACY 0.005
PARAMETER_RESOLUTION 0.001
PARAMETER TEMP
PARAMETER_SEMSOR CTD_TEMP
PARAMETER_UNITS degree_Celsius
PARAMETER_ACCURACY 0.002
PARAMETER_RESOLUTION 0.001
Float calibration information
PREDEPLOYMENT_CALIB_EQUATION Pressure(psia)=PA0+PA1*n+PA2*n^2 where n=(output-PTCA0+PTCA1*t+PTCA2*t^2)*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2), t=PTHA0+PTHA1*y+PTHA2*y^2, y=thermistor_output
PREDEPLOYMENT_CALIB_COEFFICIENT PA0=1.130385e+00 PA1=1.408588e-01 PA2=-3.780538e-08 PTCA0=6.381172e+01 PTCA1=4.691880e-01 PTCA2=-4.600980e-03 PTCB0=2.521300e+01 PTCB1=1.400000e-03 PTCB2=0.000000e+00 PTHA0=-6.752406e+01 PTHA1=5.248839e-02 PTHA2=-6.808014e-07
PREDEPLOYMENT_CALIB_COMMENT calibrated at 2011/11/22
PREDEPLOYMENT_CALIB_EQUATION Conductivity(S/m)=(g+h*f^2+i*f^3+j*f^4)/(1+CTcor*t+CPcor*p) where f=output*sqrt(1.0+WBOTC*t)/1000, t=TEMP, p=PRES
PREDEPLOYMENT_CALIB_COEFFICIENT g=-9.852176e-01 h=1.400734e-01 i=-3.842837e-04 j=4.801013e-05 CPCOR=-9.570001e-08 CTCOR=3.250000e-06 WBOTC=-3.761009e-08
PREDEPLOYMENT_CALIB_COMMENT calibrated at 2011/11/25
PREDEPLOYMENT_CALIB_EQUATION Temperature[ITS-90](degC)=1/{a0+a1[ln(n)]+a2[ln^2(n)]+a3[ln^3(n)]}-273.15 where n=output
PREDEPLOYMENT_CALIB_COEFFICIENT a0=3.490032e-05 a1=2.725332e-04 a2=-2.331672e-06 a3=1.467510e-07
PREDEPLOYMENT_CALIB_COMMENT calibrated at 2011/11/25
Configuration parameters
CONFIG_AscentTime_hours 6.173
CONFIG_CycleTime_hours 120
CONFIG_Direction_NUMBER 1
CONFIG_DownTime_hours 101
CONFIG_MissionPreludeTime_hours 6
CONFIG_ParkPressure_dbar 1000
CONFIG_ParkTime_hours 94.827
CONFIG_ProfilePressure_dbar 2000
CONFIG_TransmissionRepetitionPeriod_seconds 44
CONFIG_UpTime_hours 19
CONFIG_MISSION_NUMBER 0
CONFIG_AscentTime_hours 6.173
CONFIG_CycleTime_hours 120
CONFIG_Direction_NUMBER 1
CONFIG_DownTime_hours 101
CONFIG_MissionPreludeTime_hours 6
CONFIG_ParkPressure_dbar 1000
CONFIG_ParkTime_hours 94.827
CONFIG_ProfilePressure_dbar 2000
CONFIG_TransmissionRepetitionPeriod_seconds 44
CONFIG_UpTime_hours 19
CONFIG_MISSION_COMMENT none