Meta Data

(Update 3-Jun-2020 UTC)

General information on the meta-data file
DATA_TYPE none
FORMAT_VERSION 3.1
HANDBOOK_VERSION 1.2
DATE_CREATION 2014-08-20 13:58:43
DATE_UPDATE 2014-08-20 13:58:43
Float characteristics
PLATFORM_NUMBER 4900765
PTT 64200
TRANS_SYSTEM ARGOS
TRAN_SYSTEM_ID 14281
TRANS_FREQUENCY 1/42
POSITIONING_SYSTEM ARGOS
PLATFORM_FAMILY FLOAT
PLATFORM_TYPE SOLO
PLATFORM_MAKER SIO_IDG
FIRMWARE_VERSION V1.1; SBE601 17Apr06
MANUAL_VERSION V1.1
FLOAT_SERIAL_NO 2624
STANDARD_FORMAT_ID 2000011
DAC_FORMAT_ID SOLO_TS12
WMO_INST_TYPE 851
PROJECT_NAME US ARGO PROJECT
DATA_CENTRE AO
PI_NAME DEAN ROEMMICH
ANOMALY none
BATTERY_TYPE Lithium
BATTERY_PACKS 1 CPU (sn=1521); 4 PUMP (sn=4853 4854 4899 4900);
CONTROLLER_BOARD_TYPE_PRIMARY SOLO HC12 V4.2
CONTROLLER_BOARD_TYPE_SECONDARY none
CONTROLLER_BOARD_SERIAL_NO_PRIMARY 4487
CONTROLLER_BOARD_SERIAL_NO_SECONDARY none
SPECIAL_FEATURES none
FLOAT_OWNER none
OPERATING_INSTITUTION SIO
CUSTOMISATION none
Float deployment and mission information
LAUNCH_DATE 2013-07-02 00:58:25
LAUNCH_LATITUDE 9.703
LAUNCH_LONGITUDE -96.419
LAUNCH_QC 1
START_DATE 2013-07-02 00:58:25
START_DATE_QC 9
STARTUP_DATE 2013-07-02 00:58:25
STARTUP_DATE_QC none
DEPLOYMENT_PLATFORM R/V McArthur II
DEPLOYMENT_CRUISE_ID AR-06-10
DEPLOYMENT_REFERENCE_STATION_ID none
END_MISSION_DATE 2013-07-02 00:58:25
END_MISSION_STATUS T
Sensor information
SENSOR CTD_PRES
SENSOR_MAKER DRUCK
SENSOR_MODEL DRUCK_2900PSIA
SENSOR_SERIAL_NO 10256
SENSOR CTD_TEMP
SENSOR_MAKER SBE
SENSOR_MODEL SBE41CP_V1.9
SENSOR_SERIAL_NO 1395
SENSOR CTD_CNDC
SENSOR_MAKER SBE
SENSOR_MODEL SBE41CP_V1.9
SENSOR_SERIAL_NO 1395
Float parameter information
PARAMETER PRES
PARAMETER_SEMSOR CTD_PRES
PARAMETER_UNITS dbar
PARAMETER_ACCURACY 1.5%
PARAMETER_RESOLUTION 0.01 dbar
PARAMETER TEMP
PARAMETER_SEMSOR CTD_TEMP
PARAMETER_UNITS degC (ITS-90)
PARAMETER_ACCURACY 0.002 degC
PARAMETER_RESOLUTION 0.0001 degC
PARAMETER PSAL
PARAMETER_SEMSOR CTD_CNDC
PARAMETER_UNITS psu
PARAMETER_ACCURACY 0.002 psu
PARAMETER_RESOLUTION 0.0001 psu
Float calibration information
PREDEPLOYMENT_CALIB_EQUATION y=thermistor output;t=PTHA0+PTHA1*y+PTHA2*y^2;x=pressure output-PTCA0-PTCA1*t-PTCA2*t^2;n=x*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2);pressure(psia)=PA0+PA1*n+PA2*n^2;
PREDEPLOYMENT_CALIB_COEFFICIENT PA0 = 2.508625E-01 PA1 = 1.388165E-01 PA2 = -3.793562E-08 PTCA0 = -1.130175E+02 PTCA1 = -1.056068E-02 PTCA2 = 3.961837E-03 PTCB0 = 2.478263E+01 PTCB1 = -7.500000E-05 PTCB2 = 0.000000E+00 PTHA0 = -7.163722E+01 PTHA1 = 5.078957E-02 PTHA2 = -4.545919E-07 POFFSET = 0.000000E+00
PREDEPLOYMENT_CALIB_COMMENT Pressure Calibration Date 20 07 2006
PREDEPLOYMENT_CALIB_EQUATION Temperature (ITS-90) = 1/{a0+a1[ln(n)]+a2[ln^2(n)]+a3[ln^3(n)]}-273.15 (oC);
PREDEPLOYMENT_CALIB_COEFFICIENT TA0 = -3.884984E-05 TA1 = 2.882013E-04 TA2 = -3.326206E-06 TA3 = 1.832395E-07
PREDEPLOYMENT_CALIB_COMMENT Temperature Calibration Date 20 07 2006
PREDEPLOYMENT_CALIB_EQUATION f=INST_FREQ*sqrt(1.0+wBOTC*t)/1000.0;Conductivity=(g+h*f^2+i*f^3+j*f^4)/(1+delta*t+epsilon*p) Siemens/meter;t=temperature[degC];p=pressure[dbar];delta=CTcor;epsilon=CPcor;
PREDEPLOYMENT_CALIB_COEFFICIENT G = -1.024012E+00 H = 1.568840E-01 I = -4.012838E-04 J =
Configuration parameters
CONFIG_ProfilePressure_dbar 1020
CONFIG_ParkPressure_dbar 1000
CONFIG_AscentToSurfaceTimeOut_hours 3.17
CONFIG_DescentToParkTimeOut_hours 8.59
CONFIG_DescentToProfTimeOut_hours 8.59
CONFIG_ParkTime_hours 8.96
CONFIG_SeeksToParkPeriods_COUNT 2
CONFIG_SeeksToParkPeriodsIntervals_seconds 7200
CONFIG_SurfaceTimeOut_hours 14
CONFIG_CycleTime_hours 240.72
CONFIG_MISSION_NUMBER 0
CONFIG_ProfilePressure_dbar 1020
CONFIG_ParkPressure_dbar 1000
CONFIG_AscentToSurfaceTimeOut_hours 3.17
CONFIG_DescentToParkTimeOut_hours 8.59
CONFIG_DescentToProfTimeOut_hours 8.59
CONFIG_ParkTime_hours 8.96
CONFIG_SeeksToParkPeriods_COUNT 2
CONFIG_SeeksToParkPeriodsIntervals_seconds 7200
CONFIG_SurfaceTimeOut_hours 14
CONFIG_CycleTime_hours 240.72
CONFIG_MISSION_COMMENT none