Meta Data

(Update 23-Sep-2020 UTC)

General information on the meta-data file
DATA_TYPE none
FORMAT_VERSION 3.1
HANDBOOK_VERSION 1.2
DATE_CREATION 2015-06-14 02:25:17
DATE_UPDATE 2015-06-14 02:25:17
Float characteristics
PLATFORM_NUMBER 5900491
PTT 20904
TRANS_SYSTEM ARGOS
TRAN_SYSTEM_ID 02147
TRANS_FREQUENCY 401650000
POSITIONING_SYSTEM ARGOS
PLATFORM_FAMILY FLOAT
PLATFORM_TYPE APEX
PLATFORM_MAKER WRC
FIRMWARE_VERSION 061703
MANUAL_VERSION 062303
FLOAT_SERIAL_NO 1086
STANDARD_FORMAT_ID 001021
DAC_FORMAT_ID A5
WMO_INST_TYPE 846
PROJECT_NAME J-ARGO
DATA_CENTRE JA
PI_NAME JAMSTEC
ANOMALY none
BATTERY_TYPE Alkaline
BATTERY_PACKS none
CONTROLLER_BOARD_TYPE_PRIMARY APF8c
CONTROLLER_BOARD_TYPE_SECONDARY none
CONTROLLER_BOARD_SERIAL_NO_PRIMARY 1385
CONTROLLER_BOARD_SERIAL_NO_SECONDARY none
SPECIAL_FEATURES none
FLOAT_OWNER JAMSTEC
OPERATING_INSTITUTION JAMSTEC
CUSTOMISATION none
Float deployment and mission information
LAUNCH_DATE 2005-07-05 00:05:34
LAUNCH_LATITUDE -8.0075
LAUNCH_LONGITUDE -146.7397
LAUNCH_QC 1
START_DATE 2005-07-05 00:05:34
START_DATE_QC 1
STARTUP_DATE 2005-07-05 00:05:34
STARTUP_DATE_QC 1
DEPLOYMENT_PLATFORM Umitakamaru
DEPLOYMENT_CRUISE_ID UM012
DEPLOYMENT_REFERENCE_STATION_ID none
END_MISSION_DATE 2005-07-05 00:05:34
END_MISSION_STATUS T
Sensor information
SENSOR CTD_PRES
SENSOR_MAKER DRUCK
SENSOR_MODEL DRUCK
SENSOR_SERIAL_NO 4644
SENSOR CTD_TEMP
SENSOR_MAKER SBE
SENSOR_MODEL SBE41
SENSOR_SERIAL_NO 1102
SENSOR CTD_CNDC
SENSOR_MAKER SBE
SENSOR_MODEL SBE41
SENSOR_SERIAL_NO 1102
Float parameter information
PARAMETER PRES
PARAMETER_SEMSOR CTD_PRES
PARAMETER_UNITS decibar
PARAMETER_ACCURACY 2.4
PARAMETER_RESOLUTION 0.1
PARAMETER PSAL
PARAMETER_SEMSOR CTD_CNDC
PARAMETER_UNITS psu
PARAMETER_ACCURACY 0.005
PARAMETER_RESOLUTION 0.001
PARAMETER TEMP
PARAMETER_SEMSOR CTD_TEMP
PARAMETER_UNITS degree_Celsius
PARAMETER_ACCURACY 0.002
PARAMETER_RESOLUTION 0.001
Float calibration information
PREDEPLOYMENT_CALIB_EQUATION y = thermistor output; t = PTHA0 + PTHA1 * y + PTHA2 * y^2; x = pressure output - PTCA0 - PTCA1 * t - PTCA2 * t^2; n = x * PTCB0 / (PTCB0 + PTCB1 * t + PTCB2 * t^2); pressure (psia) = PA0 + PA1 * n + PA2 * n^2;
PREDEPLOYMENT_CALIB_COEFFICIENT PA0=-1.251775e-01, PA1=1.372281e-01, PA2=-3.716751e-08, PTHA0=-6.740512e+01, PTHA1=4.697477e-02, PTHA2=3.599431e-07, PTCA0=-9.738480e+01, PTCA1=7.644539e-02, PTCA2=-5.017745e-03, PTCB0=2.507825e+01, PTCB1=-7.500000e-04, PTCB2=.000000e+00
PREDEPLOYMENT_CALIB_COMMENT Calibrated on 10/Oct/2003
PREDEPLOYMENT_CALIB_EQUATION f = INST FREQ * sqrt(1.0 + WBOTC * t) / 1000.0; Conductivity = (g + h * f^2+ i * f^3 + j * f^4) / (1 + d * t + e * p) Siemens / meter; t = temperature[degree C]; p = pressure[decibars]; d = CTcor; e = CPcor;
PREDEPLOYMENT_CALIB_COEFFICIENT g=-1.060227e+00, h=1.534022e-01, i=-2.255989e-04, j=4.110331e-05, CPcor=-9.570000e-08, CTcor=3.250000e-06, WBOTC=-3.925807e-06
PREDEPLOYMENT_CALIB_COMMENT Calibrated on 11/Oct/2003
PREDEPLOYMENT_CALIB_EQUATION Temperature ITS-90 = 1/{a0 + a1[ln(n)] + a2[ln^2(n)] + a3[ln^3(n)]} - 273.15 (degree C); n = instrument output;
PREDEPLOYMENT_CALIB_COEFFICIENT a0=3.284869e-06, a1=2.772890e-04, a2=-2.623752e-06, a3=1.606111e-07
PREDEPLOYMENT_CALIB_COMMENT Calibrated on 11/Oct/2003
Configuration parameters
CONFIG_CycleTime_hours 240
CONFIG_ParkPressure_dbar 1000
CONFIG_ProfilePressure_dbar 2000
CONFIG_Direction_NUMBER 1
CONFIG_TransmissionRepetitionPeriod_seconds 30
CONFIG_DownTime_hours 219
CONFIG_UpTime_hours 21
CONFIG_AscentTime_hours 6.173
CONFIG_ParkTime_hours 212.827
CONFIG_AscentToSurfaceTimeOut_hours 11
CONFIG_MissionPreludeTime_hours 6
CONFIG_DepthTable_NUMBER 51
CONFIG_ParkAndProfileCycleCounter_COUNT 1
CONFIG_PistonFullExtension_COUNT 251
CONFIG_OkVacuum_COUNT 115
CONFIG_PressureBladderMax_COUNT 145
CONFIG_MISSION_NUMBER 0
CONFIG_CycleTime_hours 240
CONFIG_ParkPressure_dbar 1000
CONFIG_ProfilePressure_dbar 2000
CONFIG_Direction_NUMBER 1
CONFIG_TransmissionRepetitionPeriod_seconds 30
CONFIG_DownTime_hours 219
CONFIG_UpTime_hours 21
CONFIG_AscentTime_hours 6.173
CONFIG_ParkTime_hours 212.827
CONFIG_AscentToSurfaceTimeOut_hours 11
CONFIG_MissionPreludeTime_hours 6
CONFIG_DepthTable_NUMBER 51
CONFIG_ParkAndProfileCycleCounter_COUNT 1
CONFIG_PistonFullExtension_COUNT 251
CONFIG_OkVacuum_COUNT 115
CONFIG_PressureBladderMax_COUNT 145
CONFIG_MISSION_COMMENT none