Meta Data

(Update 2-Jun-2020 UTC)

General information on the meta-data file
DATA_TYPE none
FORMAT_VERSION 3.1
HANDBOOK_VERSION 1.2
DATE_CREATION 2015-12-18 13:37:25
DATE_UPDATE 2015-12-18 13:37:25
Float characteristics
PLATFORM_NUMBER 5902211
PTT 45832
TRANS_SYSTEM ARGOS
TRAN_SYSTEM_ID 14281
TRANS_FREQUENCY 1/43
POSITIONING_SYSTEM ARGOS
PLATFORM_FAMILY FLOAT
PLATFORM_TYPE SOLO
PLATFORM_MAKER SIO_IDG
FIRMWARE_VERSION V1.2; SBE601 22Jan08
MANUAL_VERSION V1.2
FLOAT_SERIAL_NO 2837
STANDARD_FORMAT_ID 2000012
DAC_FORMAT_ID SOLO_TS12
WMO_INST_TYPE 851
PROJECT_NAME US ARGO PROJECT
DATA_CENTRE AO
PI_NAME DEAN ROEMMICH
ANOMALY none
BATTERY_TYPE Lithium
BATTERY_PACKS 1 CPU (sn=1751); 4 PUMP (sn=5505 5504 5308 5309);
CONTROLLER_BOARD_TYPE_PRIMARY SOLO HC12 V4.2
CONTROLLER_BOARD_TYPE_SECONDARY none
CONTROLLER_BOARD_SERIAL_NO_PRIMARY 4729
CONTROLLER_BOARD_SERIAL_NO_SECONDARY none
SPECIAL_FEATURES none
FLOAT_OWNER none
OPERATING_INSTITUTION SIO
CUSTOMISATION none
Float deployment and mission information
LAUNCH_DATE 2015-11-26 15:00:31
LAUNCH_LATITUDE 23.877
LAUNCH_LONGITUDE -150.004
LAUNCH_QC 1
START_DATE 2015-11-26 15:00:31
START_DATE_QC 9
STARTUP_DATE 2015-11-26 15:00:31
STARTUP_DATE_QC 9
DEPLOYMENT_PLATFORM R/V Kilo Moana
DEPLOYMENT_CRUISE_ID none
DEPLOYMENT_REFERENCE_STATION_ID none
END_MISSION_DATE 2015-11-26 15:00:31
END_MISSION_STATUS T
Sensor information
SENSOR CTD_PRES
SENSOR_MAKER DRUCK
SENSOR_MODEL DRUCK_2900PSIA
SENSOR_SERIAL_NO 2632671
SENSOR CTD_TEMP
SENSOR_MAKER SBE
SENSOR_MODEL SBE41CP_V2
SENSOR_SERIAL_NO 2336
SENSOR CTD_CNDC
SENSOR_MAKER SBE
SENSOR_MODEL SBE41CP_V2
SENSOR_SERIAL_NO 2336
Float parameter information
PARAMETER PRES
PARAMETER_SEMSOR CTD_PRES
PARAMETER_UNITS dbar
PARAMETER_ACCURACY 1.5%
PARAMETER_RESOLUTION 0.01 dbar
PARAMETER TEMP
PARAMETER_SEMSOR CTD_TEMP
PARAMETER_UNITS degC (ITS-90)
PARAMETER_ACCURACY 0.002 degC
PARAMETER_RESOLUTION 0.0001 degC
PARAMETER PSAL
PARAMETER_SEMSOR CTD_CNDC
PARAMETER_UNITS psu
PARAMETER_ACCURACY 0.002 psu
PARAMETER_RESOLUTION 0.0001 psu
Float calibration information
PREDEPLOYMENT_CALIB_EQUATION y=thermistor output;t=PTHA0+PTHA1*y+PTHA2*y^2;x=pressure output-PTCA0-PTCA1*t-PTCA2*t^2;n=x*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2);pressure(psia)=PA0+PA1*n+PA2*n^2;
PREDEPLOYMENT_CALIB_COEFFICIENT PA0 = -9.536262E-02 PA1 = 1.375035E-01 PA2 = -3.352215E-08 PTCA0 = 1.981412E+01 PTCA1 = -3.316057E-03 PTCA2 = -1.275094E-03 PTCB0 = 2.610688E+01 PTCB1 = 1.975000E-03 PTCB2 = 0.000000E+00 PTHA0 = -7.268816E+01 PTHA1 = 4.757489E-02 PTHA2 = 2.443872E-07 POFFSET = 0.000000E+00
PREDEPLOYMENT_CALIB_COMMENT Pressure Calibration Date 18 09 2008
PREDEPLOYMENT_CALIB_EQUATION Temperature (ITS-90) = 1/{a0+a1[ln(n)]+a2[ln^2(n)]+a3[ln^3(n)]}-273.15 (oC);
PREDEPLOYMENT_CALIB_COEFFICIENT TA0 = -5.689042E-05 TA1 = 2.774139E-04 TA2 = -2.524126E-06 TA3 = 1.531535E-07
PREDEPLOYMENT_CALIB_COMMENT Temperature Calibration Date 18 09 2008
PREDEPLOYMENT_CALIB_EQUATION f=INST_FREQ*sqrt(1.0+wBOTC*t)/1000.0;Conductivity=(g+h*f^2+i*f^3+j*f^4)/(1+delta*t+epsilon*p) Siemens/meter;t=temperature[degC];p=pressure[dbar];delta=CTcor;epsilon=CPcor;
PREDEPLOYMENT_CALIB_COEFFICIENT G = -1.004257E+00 H = 1.532146E-01 I = -3.781359E-04 J =
Configuration parameters
CONFIG_ProfilePressure_dbar 1206
CONFIG_ParkPressure_dbar 1000
CONFIG_AscentToSurfaceTimeOut_hours 8.61
CONFIG_DescentToParkTimeOut_hours 8.61
CONFIG_DescentToProfTimeOut_hours 8.61
CONFIG_ParkTime_hours 8.94
CONFIG_SeeksToParkPeriods_COUNT 2
CONFIG_SeeksToParkPeriodsIntervals_seconds 7200
CONFIG_SurfaceTimeOut_hours 14
CONFIG_CycleTime_hours 245.9
CONFIG_MISSION_NUMBER 0
CONFIG_ProfilePressure_dbar 1206
CONFIG_ParkPressure_dbar 1000
CONFIG_AscentToSurfaceTimeOut_hours 8.61
CONFIG_DescentToParkTimeOut_hours 8.61
CONFIG_DescentToProfTimeOut_hours 8.61
CONFIG_ParkTime_hours 8.94
CONFIG_SeeksToParkPeriods_COUNT 2
CONFIG_SeeksToParkPeriodsIntervals_seconds 7200
CONFIG_SurfaceTimeOut_hours 14
CONFIG_CycleTime_hours 245.9
CONFIG_MISSION_COMMENT none