Meta Data

(Update 1-Jun-2020 UTC)

General information on the meta-data file
DATA_TYPE none
FORMAT_VERSION 3.1
HANDBOOK_VERSION 1.2
DATE_CREATION 2018-01-17 17:24:03
DATE_UPDATE 2018-01-17 17:24:03
Float characteristics
PLATFORM_NUMBER 5903817
PTT 49912
TRANS_SYSTEM ARGOS
TRAN_SYSTEM_ID 14281
TRANS_FREQUENCY 1/42
POSITIONING_SYSTEM ARGOS
PLATFORM_FAMILY FLOAT
PLATFORM_TYPE SOLO
PLATFORM_MAKER SIO_IDG
FIRMWARE_VERSION V1.2; SBE601 16Mar10
MANUAL_VERSION V1.2
FLOAT_SERIAL_NO 3026
STANDARD_FORMAT_ID 2000012
DAC_FORMAT_ID SOLO_TS12
WMO_INST_TYPE 851
PROJECT_NAME US ARGO PROJECT
DATA_CENTRE AO
PI_NAME DEAN ROEMMICH
ANOMALY none
BATTERY_TYPE Lithium
BATTERY_PACKS 1 CPU (sn=1922); 4 PUMP (sn=6996 6997 6998 6999);
CONTROLLER_BOARD_TYPE_PRIMARY HC12 Rev:4.2
CONTROLLER_BOARD_TYPE_SECONDARY none
CONTROLLER_BOARD_SERIAL_NO_PRIMARY 4996
CONTROLLER_BOARD_SERIAL_NO_SECONDARY none
SPECIAL_FEATURES none
FLOAT_OWNER none
OPERATING_INSTITUTION SIO
CUSTOMISATION none
Float deployment and mission information
LAUNCH_DATE 2017-10-23 08:51:43
LAUNCH_LATITUDE -53.986
LAUNCH_LONGITUDE 120.702
LAUNCH_QC 1
START_DATE 2017-10-23 08:51:43
START_DATE_QC 9
STARTUP_DATE 2017-10-23 08:51:43
STARTUP_DATE_QC 9
DEPLOYMENT_PLATFORM M/V Aurora
DEPLOYMENT_CRUISE_ID none
DEPLOYMENT_REFERENCE_STATION_ID none
END_MISSION_DATE 2017-10-23 08:51:43
END_MISSION_STATUS T
Sensor information
SENSOR CTD_PRES
SENSOR_MAKER DRUCK
SENSOR_MODEL DRUCK_2900PSIA
SENSOR_SERIAL_NO 3244233
SENSOR CTD_TEMP
SENSOR_MAKER SBE
SENSOR_MODEL SBE41CP_V3.0a
SENSOR_SERIAL_NO 3666
SENSOR CTD_CNDC
SENSOR_MAKER SBE
SENSOR_MODEL SBE41CP_V3.0a
SENSOR_SERIAL_NO 3666
Float parameter information
PARAMETER PRES
PARAMETER_SEMSOR CTD_PRES
PARAMETER_UNITS dbar
PARAMETER_ACCURACY 1.5%
PARAMETER_RESOLUTION 0.01 dbar
PARAMETER TEMP
PARAMETER_SEMSOR CTD_TEMP
PARAMETER_UNITS degC (ITS-90)
PARAMETER_ACCURACY 0.002 degC
PARAMETER_RESOLUTION 0.0001 degC
PARAMETER PSAL
PARAMETER_SEMSOR CTD_CNDC
PARAMETER_UNITS psu
PARAMETER_ACCURACY 0.002 psu
PARAMETER_RESOLUTION 0.0001 psu
Float calibration information
PREDEPLOYMENT_CALIB_EQUATION y=thermistor output;t=PTHA0+PTHA1*y+PTHA2*y^2;x=pressure output-PTCA0-PTCA1*t-PTCA2*t^2;n=x*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2);pressure(psia)=PA0+PA1*n+PA2*n^2;
PREDEPLOYMENT_CALIB_COEFFICIENT PA0 = 5.463775E-01 PA1 = 1.404736E-01 PA2 = -4.126459E-08 PTCA0 = 5.893257E+01 PTCA1 = 3.466910E-01 PTCA2 = -7.714480E-03 PTCB0 = 2.526213E+01 PTCB1 = -5.750000E-04 PTCB2 = 0.000000E+00 PTHA0 = -7.682191E+01 PTHA1 = 5.034734E-02 PTHA2 = -6.324336E-07 POFFSET = 0.000000E+00
PREDEPLOYMENT_CALIB_COMMENT Pressure Calibration Date 03 08 2011
PREDEPLOYMENT_CALIB_EQUATION Temperature (ITS-90) = 1/{a0+a1[ln(n)]+a2[ln^2(n)]+a3[ln^3(n)]}-273.15 (oC);
PREDEPLOYMENT_CALIB_COEFFICIENT TA0 = -1.486861E-05 TA1 = 2.769784E-04 TA2 = -2.645267E-06 TA3 = 1.542451E-07
PREDEPLOYMENT_CALIB_COMMENT Temperature Calibration Date 03 08 2011
PREDEPLOYMENT_CALIB_EQUATION f=INST_FREQ*sqrt(1.0+wBOTC*t)/1000.0;Conductivity=(g+h*f^2+i*f^3+j*f^4)/(1+delta*t+epsilon*p) Siemens/meter;t=temperature[degC];p=pressure[dbar];delta=CTcor;epsilon=CPcor;
PREDEPLOYMENT_CALIB_COEFFICIENT G = -9.948985E-01 H = 1.436612E-01 I = -3.978775E-04 J =
Configuration parameters
CONFIG_ProfilePressure_dbar 1866
CONFIG_ParkPressure_dbar 1000
CONFIG_AscentToSurfaceTimeOut_hours 13.1
CONFIG_DescentToParkTimeOut_hours 8.6
CONFIG_DescentToProfTimeOut_hours 8.6
CONFIG_ParkTime_hours 9
CONFIG_SeeksToParkPeriods_COUNT 2
CONFIG_SeeksToParkPeriodsIntervals_seconds 7200
CONFIG_SurfaceTimeOut_hours 12
CONFIG_CycleTime_hours 249.7
CONFIG_MISSION_NUMBER 0
CONFIG_ProfilePressure_dbar 1866
CONFIG_ParkPressure_dbar 1000
CONFIG_AscentToSurfaceTimeOut_hours 13.1
CONFIG_DescentToParkTimeOut_hours 8.6
CONFIG_DescentToProfTimeOut_hours 8.6
CONFIG_ParkTime_hours 9
CONFIG_SeeksToParkPeriods_COUNT 2
CONFIG_SeeksToParkPeriodsIntervals_seconds 7200
CONFIG_SurfaceTimeOut_hours 12
CONFIG_CycleTime_hours 249.7
CONFIG_MISSION_COMMENT none