Hydrophone
manufactured by International Transducer Corp.
Hydrophones are mounted in the two seismometers and the cable-end station
of the Kushiro-Tokachi system.
* An enlarged version of the photograph of the exterior of the hydrophone may
be viewed by clicking the image on the right.
|
|
|
1. Hydrophone Sensor Unit
| Hydrophone Sensor |
| i) Sensor model |
ITC-1010 (A-C-Hydrophone) |
| ii) Frequency range |
5 to 200 Hz (capacity value) |
| iii) Wave reception sensitivity |
-185 dB, re1 V/micro Pai |
| iv) Beam pattern |
omn |
2. Transmission Unit
| A/D Converter |
| i) A/D converter bits |
24 bits |
| ii) Sampling frequency |
1 kHz ± 100 ppm |
| iii) Input level range |
± 4.5 V |
| iv) Filter band |
DC to 200 Hz |
3. Data Processing
Data sent from the seabed is subjected to
digital filtering processing (Fc = 40 Hz)
with a land device in order to record
and send to JAMSTEC in Yokosuka.
|
4. General Characteristic
| Transit area |
1 Hz to 40 Hz |
| Blockage area |
50 Hz or more |
* Due to the effects of the operation of the ADCP, every 30 minutes
noise arises in the OBS hydrophone data.