Hydrophone
manufactured by International Transducer Corp.


Hydrophones are mounted in the two seismometers and the cable-end station of the Kushiro-Tokachi system.

*  An enlarged version of the photograph of the exterior of the hydrophone may be viewed by clicking the image on the right.

Hydrophone


1. Hydrophone Sensor Unit
 Hydrophone Sensor
  i)   Sensor model  ITC-1010 (A-C-Hydrophone)
  ii)  Frequency range  5 to 200 Hz (capacity value)
  iii)  Wave reception sensitivity  -185 dB, re1 V/micro Pai
  iv)  Beam pattern  omn
  
2. Transmission Unit
 A/D Converter
  i) A/D converter bits  24 bits
  ii)  Sampling frequency  1 kHz ± 100 ppm
  iii) Input level range  ± 4.5 V    
  iv)  Filter band  DC to 200 Hz            
  
3. Data Processing
Data sent from the seabed is subjected to digital filtering processing (Fc = 40 Hz) with a land device in order to record and send to JAMSTEC in Yokosuka.
  
4. General Characteristic
Transit area  1 Hz to 40 Hz
Blockage area  50 Hz or more

*  Due to the effects of the operation of the ADCP, every 30 minutes noise arises in the OBS hydrophone data.