Basically, the sampling ratio for m-TRITON system is as same as the TRITON system to ensure data compatibility; i.e., every 10 -minute for internal record (current meter is every 20-minute), and hourly averaged data for real time data transmission via ARGOS satellite communication system.
In future, the 10-minute data can be transmitted via next generation ARGOS III system.
Table 1: m-TRITON sensor sampling
|
Sample rate or response time
|
Average period in each sensor unit/1sample |
sample period in m-TRITON data processor
|
Sample time |
|
Real time data |
|
5 sec. integration
1/5 sec.
1/5 sec.
|
|
|
00:09-00:11
00:19-00:21...
|
|
hourly mean
ex. UTC01:00 data
(00:09-00:11
00:19-00:21...
00:59-01:01)
|
|
1/2 sec. |
1 min.-Ave. |
2 samples Ave./2 min. |
00:09-00:11
00:19-00-21... |
every 10 min. |
hourly mean
(same as above) |
|
1/10 sec. |
1 min.-Ave. |
2 samples Ave./2 min. |
00:09-00:11
00:19-00-21... |
every 10 min. |
hourly mean
(same as above) |
|
1/10 sec. |
1 min.-Ave. |
2 samples Ave./2 min. |
00:09-00:11
00:19-00:21... |
every 10 min. |
hourly mean
(same as above) |
Precipitation |
1/5 sec. |
1 min.-integration |
10 samples integration/10 min. |
00:00-00:10
00:10-00:20... |
every 10 min.
(ex. UTC 00:10 10-min. data; 00:00-00:10) |
hourly mean
(ex. UTC 01:00 data
00:00-00:10
00:10-00:20...
00:50-01:00) |
CTD/TD |
sensor response time 3.4-4.3 sec. |
7 sec. Ave. |
1 sample/10 min. |
00:10
00:20... |
every 10 min. |
hourly mean
(ex. UTC 01:00 data
00:10
00:20...
01:00) |
Current vector |
1 ping/1 sec. |
2 min.-vector Ave. |
1 sample/2 min. |
00:09-00:11
00:29-00:31... |
every 20 min. |
hourly mean
(ex. UTC 01:00 data
00:09-00:11
00:29-00:31
00:49-00:51)
|
|
 |