defaultStatus = "JavaScript off";

Data Sampling Return

Basically, the sampling ratio for m-TRITON system is as same as the TRITON system to ensure data compatibility; i.e., every 10 -minute for internal record (current meter is every 20-minute), and hourly averaged data for real time data transmission via ARGOS satellite communication system.

In future, the 10-minute data can be transmitted via next generation ARGOS III system.


Table 1: m-TRITON sensor sampling

Sensor
Sample rate or response time
Average period in each sensor unit/1sample
sample period in m-TRITON data processor
Sample time
Data recorded in memory
Real time data

WindVector

 

speed

vane

compass

 

1/5 sec.

 

5 sec. integration

1/5 sec.

1/5 sec.

 

1 min. vector Ave.

 

 

 

 

 

2 samples Ave. / 2 min.

 

 

 

 

 

00:09-00:11

00:19-00:21...

 

 

 

every 10 min.

 

 

 

 

 

hourly mean

ex. UTC01:00 data

(00:09-00:11

00:19-00:21...

00:59-01:01)

Shorwave radiation

1/2 sec.

1 min.-Ave.
2 samples Ave./2 min.

00:09-00:11

00:19-00-21...

every 10 min.

hourly mean

(same as above)

Relative humidity
1/10 sec.
1 min.-Ave.
2 samples Ave./2 min.

00:09-00:11

00:19-00-21...

every 10 min.

hourly mean

(same as above)

Air temperature
1/10 sec.
1 min.-Ave.
2 samples Ave./2 min.

00:09-00:11

00:19-00:21...

every 10 min.

hourly mean

(same as above)

Precipitation
1/5 sec.
1 min.-integration
10 samples integration/10 min.

00:00-00:10

00:10-00:20...

every 10 min.

(ex. UTC 00:10 10-min. data; 00:00-00:10)

hourly mean

(ex. UTC 01:00 data

00:00-00:10

00:10-00:20...

00:50-01:00)

CTD/TD
sensor response time 3.4-4.3 sec.
7 sec. Ave.
1 sample/10 min.

00:10

00:20...

every 10 min.

hourly mean

(ex. UTC 01:00 data

00:10

00:20...

01:00)

Current vector
1 ping/1 sec.
2 min.-vector Ave.
1 sample/2 min.

00:09-00:11

00:29-00:31...

every 20 min.

hourly mean

(ex. UTC 01:00 data

00:09-00:11

00:29-00:31

00:49-00:51)