Hole C0013F, Expedition 331
Lineage
This URL provides the access to the most recent output from the database. The output is being overwritten as often as possible.
This data set was output from J-CORES database by using its complete Bulk Export function Version 1.9.9 from 2018-01-23T17:20:03Z till 2018-01-23T17:20:17Z.
The specification of the outputs is available to be referred.
Bulk Export gives a file bulk.csv
with various attachment files (e.g. image files).
Files bulk-something.csv
are generated
by picking some kinds of data from bulk.csv
.
Files something.zip
consist of
bulk-something.csv
and related attachment files.
Files bulk-something.csv
are in character encoding UTF-8
with line ending characters CRLF
.
The database has a flexibility to store numerical/text values and attached files for user-defined parameters,
which are output into User-Defined Parameter column group
in bulk.csv
.
Data file index
File | Contents | Length (bytes) |
---|---|---|
bulk-hole.csv | Expedition, site and hole records | 987 |
bulk-core.csv | Core drilling and curatorial records | 1218 |
bulk-section.csv | Core section records | 3805 |
sample.zip | Records of ship and personal samples taken from core sections and miscellaneous materials | 6838 |
vcd.zip | Visual core descriptions (VCD) | 445601 |
microbiology.zip | Microbiology, including contamination tests | 618 |
xray-ct-scanner.zip | X-ray CT scanned coronal images of core sections | 1963102 |
mscl.zip | Physical properties by Multi Sensor Core Logger(s) (MSCL) | 81381 |
split-section-image.zip | Images of split halves of core sections | 3176335 |
moisture-density.zip | Moisture and density (MAD) for discrete samples | 2077 |
thermal-conductivity.zip | Thermal conductivity for core sections | 1209 |
bulk-electrical-conductivity.csv | Electrical conductivity for discrete samples | 2104 |
bulk-particle-size-analysis.csv | Particle size distribution for discrete samples | 1949 |
xrd.zip | XRD for bulk discrete samples | 414790 |
headspace-gas.zip | Headspace gas analyses | 969 |
pore-water-chemistry.zip | Chemistry for pore water | 11188874 |
bulk-cns-analysis.zip | Bulk CNS analyses for discrete samples | 1624 |
downhole-measurement.zip | Downhole measurements | 737 |
Parameter definitions
The user-defined parameters are listed with their definitions as the followings.
- X-ray CT scanning
-
X-ray CT scanned images for core sections. The right-handed coordinate system is
applied to each core section as the followings. Y axis is from the working half
toward the archive half. Z axis is from the core bottom toward the top. (x, y,
z) = (0, 0, 0) at the center of the top of the core section.
- X-ray CT scanning::coronal image
- The cross section at the boundary of the working and archive halves of the core section, looking the archive half side. In other words, the x-z plane (y = 0), looking to the negative y. The image is created by compiling the series of axial images, at each of which z is a constant. The file is formatted in DICOM.
- X-ray CT scanning::top margin [pixels]
- Height of the margin at the top of the image. Not always integer. number of pixels in raster graphics
- X-ray CT scanning::bottom margin [pixels]
- Height of the margin at the bottom of the image. Not always integer. number of pixels in raster graphics
- X-ray CT scanning::each side margin [pixels]
- Width of the margin at each of the right and the left of the image. Not always integer. number of pixels in raster graphics
- split section image
-
Images for split core sections. At the top and the right there are no margins.
- split section image::line scanned image
- A surface image acquired by a line scan camera.
- split section image::bottom margin [pixels]
- Height of the margin at the bottom of the image. Not always integer. number of pixels in raster graphics
- PFT contamination test; sample
-
Contamination test by perfluorocarbon tracers (PFT) for bulk samples.
- PFT contamination test; sample::PFT concentration: GC-ECD; headspace, interior [µg/L]
- Perfluorocarbon tracer (PFT) concentration in headspace of interior sample, by measuring headspace gas sample by using a gas chromatograph with a electron capture detector. micro-gram per liter
- PFT contamination test; sample::PFT concentration: GC-ECD; headspace, exterior [µg/L]
- Perfluorocarbon tracer (PFT) concentration in headspace of exterior sample, by measuring headspace gas sample by using a gas chromatograph with a electron capture detector. micro-gram per liter
- MSCL; section
-
Measurements for core sections by using a Multi Sensor Core Logger (MSCL).
- MSCL; section::section half
- Whether whole-round core sections or split halves of core sections and which side of split halves, for which the measurement is conducted. The values for this parameter have to be chosen from `whole-round', `archive', `working' and `either half'.
- MSCL; section::GRA density: horizontal sensor direction [g/cm3]
- Density calculated with Gamma Ray Attenuation (GRA) method. The sensor, a set of an RI source (137Cs) and a scintilation detector, is attached in the horizontal direction on the track of the Multi Sensor Core Logger (i.e., gamma ray beam passes through at the split point between working and archive halves). gram per cubic centi-meter
- MSCL; section::P-wave velocity: ARC transducer, 230 kHz [m/s]
- Measured P-wave velocity. The P-wave transducer is an oil filled acoustinc rolling contract (ARC) transducer. A set of the transmitter and a receiver, is attached in the horizontal direction on the track of the Multi Sensor Core Logger (i.e., P-wave passes through at the split point between working and archive halves). P-wave pulse which is an ultrasonic compressional pulse generated by a piezoelectric crystal is 230 kHz. meter per second
- MSCL; section::P-wave signal amplitude: ARC transducer, 230 kHz
- Measured P-wave signal amplitude. The P-wave transducer is an oil filled acoustinc rolling contract (ARC) transducer. A set of the transmitter and a receiver, is attached in the horizontal direction on the track of the Multi Sensor Core Logger (i.e., P-wave passes through at the split point between working and archive halves). P-wave pulse which is an ultrasonic compressional pulse generated by a piezoelectric crystal is 230 kHz. dimensionless quantity
- MSCL; section::natural gamma radiation: detector set #1, 80 mm [CPS]
- Counts per seconds of detected gamma ray photons. This count is a total of four scintillation detectors. Each of the four detectors is combined with a multichannel analyser. They are attached in a cross shape on a central lead cube which is on the track of the Multi Sensor Core Logger. Serial number of the each detector is; the upper side (a detector at the direction of 12 o'clock from the view in the core movement direction) is 04L033, the right side (at 3 o'clock) is 04L028, the lower side (at 6 o'clock) is 04L034, and the left side (at 9 o'clock) is 04L041. The aperture of the central lead cube is 80 mm. counts per second
- thermal conductivity; section
-
Thermal conductivity measurements for core sections. Thermal conductivity is the
average value of those by iterative measurements.
- thermal conductivity; section::section half
- Whether whole-round core sections or split halves of core sections and which side of split halves, for which the measurement is conducted. The values for this parameter have to be chosen from `whole-round', `archive', `working' and `either half'.
- thermal conductivity; section::thermal conductivity [W/(m K)]
- Measured thermal conductivity value. watts per kelvin per meter
- thermal conductivity; section::number of iterative measurements
- How many iterative measurements are conducted for the measurement. dimensionless quantity
- thermal conductivity; section::thermal conductivity probe
- Type of the probe used for the thermal conductivity measurement.
- thermal conductivity; section::thermal conductivity probe serial number
- Serial number of the probe used for the thermal conductivity measurement.
- thermal conductivity iteration; section
-
Each iteration of thermal conductivity measurements for core sections.
- thermal conductivity iteration; section::section half
- Whether whole-round core sections or split halves of core sections and which side of split halves, for which the measurement is conducted. The values for this parameter have to be chosen from `whole-round', `archive', `working' and `either half'.
- thermal conductivity iteration; section::iteration number
- Sequential number to distinguish the iterative measurement, which starts from 1. dimensionless quantity
- thermal conductivity iteration; section::thermal conductivity [W/(m K)]
- Measured thermal conductivity value. watts per kelvin per meter
- thermal conductivity iteration; section::LET: TK04
- Logarithm of the extreme time (LET) value of the best solution (TK04 User's Manual; TeKa, Berlin, Germany). dimensionless quantity
- thermal conductivity iteration; section::number of solutions: TK04
- The total number of solutions found for the heating curve (TK04 User's Manual; TeKa, Berlin, Germany). dimensionless quantity
- thermal conductivity iteration; section::time start: TK04 [s]
- Start time of the evaluation interval the best solution calculated from (TK04 User's Manual; TeKa, Berlin, Germany). second
- thermal conductivity iteration; section::time length: TK04 [s]
- Length of the evaluation interval the best solution calculated from (TK04 User's Manual; TeKa, Berlin, Germany). second
- thermal conductivity iteration; section::time end: TK04 [s]
- End time of the evaluation interval the best solution calculated from (TK04 User's Manual; TeKa, Berlin, Germany). second
- thermal conductivity iteration; section::contact value: TK04
- The contact value of the heating curve (TK04 User's Manual; TeKa, Berlin, Germany). dimensionless quantity
- thermal conductivity iteration; section::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- moisture and density
-
Moisture and density (MAD) measurements for bulk samples.
- moisture and density::wet sample beaker ID
- ID of the beaker used for the wet sample.
- moisture and density::wet sample beaker type
- Type of the beaker used for the wet sample.
- moisture and density::wet sample beaker mass [g]
- Mass of the beaker used for the wet sample. gram
- moisture and density::wet sample beaker volume [cm3]
- Volume of the beaker used for the wet sample. cubic centi-meter
- moisture and density::wet sample beaker+sample mass [g]
- Mass of the wet sample with the beaker. gram
- moisture and density::wet sample beaker+sample volume: solids + pore water + beaker [cm3]
- Volume of the wet sample with the beaker, derived as the sum of volumes of solids, pore water and beaker. cubic centi-meter
- moisture and density::wet bulk mass [g]
- Mass of the wet bulk sample, derived by subtracting the beaker mass from the measurement of the sample with the beaker. gram
- moisture and density::dry sample beaker ID
- ID of the beaker used for the dry sample.
- moisture and density::dry sample beaker type
- Type of the beaker used for the dry sample.
- moisture and density::dry sample beaker mass [g]
- Mass of the beaker used for the dry sample. gram
- moisture and density::dry sample beaker volume [cm3]
- Volume of the beaker used for the dry sample. cubic centi-meter
- moisture and density::dry sample beaker+sample mass [g]
- Mass of the dry sample with the beaker. gram
- moisture and density::dry sample beaker+sample volume [cm3]
- Volume of the dry sample with the beaker. cubic centi-meter
- moisture and density::dry bulk mass [g]
- Mass of the dry bulk sample, derived by subtracting the beaker mass from the measurement of the sample with the beaker. gram
- moisture and density::pore water mass [g]
- Derived by (Mt - Md) / (1 - s), where Mt, wet bulk mass; Md, dry bulk mass; s, salinity, assumed to 0.035 M. gram
- moisture and density::pore water volume [cm3]
- Derived by Mpw / Dpw, where Mpw, pore water mass; Dpw, density, assumed to 1.024 g/cm3. cubic centi-meter
- moisture and density::solids volume: dry bulk - salt [cm3]
- Derived by subtraction of the salt volume from the dry bulk volume. cubic centi-meter
- moisture and density::wet bulk volume: solids + pore water [cm3]
- Derived as the sum of volumes of solids and pore water. cubic centi-meter
- moisture and density::dry bulk volume [cm3]
- Volume of the dry bulk sample, derived by subtracting the beaker volume from the measurement of the sample with the beaker. cubic centi-meter
- moisture and density::salt mass [g]
- Derived by (Mt - Md) s, where Mt, wet bulk mass; Md, dry bulk mass; s, salinity, assumed to 0.035. gram
- moisture and density::salt volume [cm3]
- Derived by Msalt / Dsalt, where Msalt, salt mass; Dsalt, salt density, assumed to 2.22 g/cm3. cubic centi-meter
- moisture and density::solids mass [g]
- Derived by subtraction of the salt mass from the dry bulk mass. gram
- moisture and density::water content wet
- Derived by Mpw / Mt, where Mpw, pore water mass; Mt, wet bulk mass. dimensionless quantity
- moisture and density::water content dry
- Derived by Mpw / Ms, where Mpw, pore water mass; Ms, solids mass. dimensionless quantity
- moisture and density::bulk density [g/cm3]
- Moisture and density analysis derives this by quotient of wet bulk mass by wet bulk volume. Well logging tool adnVISION may give this by another way. gram per cubic centi-meter
- moisture and density::dry density [g/cm3]
- Derived by Ms / Vt, where Ms, solids mass; Vt, wet bulk volume. gram per cubic centi-meter
- moisture and density::grain density [g/cm3]
- Derived by Ms / Vs, where Ms, solids mass; Vs, solids volume. gram per cubic centi-meter
- moisture and density::porosity
- Derived by Vpw / Vt, where Vpw, pore water volume; Vt, wet bulk volume. dimensionless quantity
- moisture and density::void ratio
- Derived by Vpw / Vs, where Vpw, pore water volume; Vs, solids volume. dimensionless quantity
- impedance analysis; section
-
Measurements by using an impedance analyzer for core sections. Electrical
impedance, resistivity and conductivity are at the frequency of the applied
alternating current. The frequency is determined by the waveform of each
measurement.
- impedance analysis; section::section half
- Whether whole-round core sections or split halves of core sections and which side of split halves, for which the measurement is conducted. The values for this parameter have to be chosen from `whole-round', `archive', `working' and `either half'.
- impedance analysis; section::formation factor Z derived by impedance analysis
- Formation factor along Z-axis derived by impedance analysis. dimensionless quantity
- particle size analysis; sample
-
Measurements by using a particle size analyzer for bulk samples.
- particle size analysis; sample::mean grain size [µm]
- Measured mean grain size. micro-meter
- particle size analysis; sample::mean grain size: organic matter removed [µm]
- Mean grain size measured after removing organic matter by processing with H2O2. micro-meter
- particle size analysis; sample::mean grain size: CaCO3 removed [µm]
- Mean grain size measured after removing CaCO3 by processing with HCl. micro-meter
- particle size analysis; sample::mean grain size: organic matter and CaCO3 removed [µm]
- Mean grain size measured after removing organic matter and CaCO3by processing with H2O2 and HCl. micro-meter
- XRD
-
Measurements by using a X-ray diffractometer for a bulk powder sample mounted on
a glass plate.
- XRD::diffraction profile, UDF
- Measurement results of X-ray diffraction measurement. The file format is the Philips UDF (ASCII). The file is converted from the RD by using X'Pert High Score, PANalytical.
- XRD::diffraction profile, RD
- Measurement results of X-ray diffraction measurement. The file format is the Philips RD (binary).
- headspace gas analysis; sample
-
Measurements for bulk samples by headspace gas analysis.
- headspace gas analysis; sample::methane concentration: GC-HID, 3rd party [ppm]
- Concentration for methane by using a third party tool gas chromatograph with a helium ionization detector. part per million
- headspace gas analysis; sample::H2 concentration: GC-HID, 3rd party [ppm]
- Concentration for hydrogen by using a third party tool gas chromatograph with a helium ionization detector. part per million
- headspace gas analysis
-
Measurements for bulk samples by headspace gas analysis.
- headspace gas analysis::methane concentration: GC-FID [ppm]
- Methane concentration by using a gas chromatograph with a flame ionization detector. part per million
- headspace gas analysis::ethylene concentration: GC-FID [ppm]
- Ethylene concentration by using a gas chromatograph with a flame ionization detector. part per million
- headspace gas analysis::ethane concentration: GC-FID [ppm]
- Ethane concentration by using a gas chromatograph with a flame ionization detector. part per million
- headspace gas analysis::propylene concentration: GC-FID [ppm]
- Propylene concentration by using a gas chromatograph with a flame ionization detector. part per million
- headspace gas analysis::propane concentration: GC-FID [ppm]
- Propane concentration by using a gas chromatograph with a flame ionization detector. part per million
- headspace gas analysis::i-butane concentration: GC-FID [ppm]
- i-butane concentration by using a gas chromatograph with a flame ionization detector. part per million
- headspace gas analysis::n-butane concentration: GC-FID [ppm]
- n-butane concentration by using a gas chromatograph with a flame ionization detector. part per million
- pore water chemistry; sample
-
Measurements for squeezed pore water samples.
- pore water chemistry; sample::refractive index nD: refractometer
- Refractive index nD using a refractometer. dimensionless quantity
- pore water chemistry; sample::chlorinity: titrator, potentiometric titration [mM]
- Chlorinity using a titrator (potentiometric titration). milli-molar
- pore water chemistry; sample::Li concentration: ICP-AES [µM]
- Lithium (Li) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry; sample::B concentration: ICP-AES [µM]
- Boron (B) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry; sample::NH4 concentration: UV-Visible spectrophotometer [mM]
- Ammonium (NH4) concentration using an ultraviolet-visible spectrophotometer. milli-molar
- pore water chemistry; sample::Na concentration: IC [mM]
- Sodium (Na) concentration using an ion-exchange chromatograph. milli-molar
- pore water chemistry; sample::Mg concentration: IC [mM]
- Magnesium (Mg) concentration using an ion-exchange chromatograph. milli-molar
- pore water chemistry; sample::Si concentration: ICP-AES [µM]
- Silicon (Si) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry; sample::Si concentration: UV-Visible spectrophotometer [mM]
- Silicon (Si) concentration using an ultraviolet-visible spectrophotometer. milli-molar
- pore water chemistry; sample::PO4 concentration: UV-Visible spectrophotometer [µM]
- Phosphate (PO4) concentration using an ultraviolet-visible spectrophotometer. micro-molar
- pore water chemistry; sample::SO4 concentration: IC [mM]
- Sulfate (SO4) concentration using an ion-exchange chromatograph. milli-molar
- pore water chemistry; sample::K concentration: IC [mM]
- Potassium (K) concentration using an ion-exchange chromatograph. milli-molar
- pore water chemistry; sample::Ca concentration: IC [mM]
- Calcium (Ca) concentration using an ion-exchange chromatograph. milli-molar
- pore water chemistry; sample::Mn concentration: ICP-AES [µM]
- Manganese (Mn) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry; sample::Fe concentration: ICP-AES [µM]
- Iron (Fe) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry; sample::Zn concentration: ICP-MS [nM]
- Zinc (Zn) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry; sample::Br concentration: IC [mM]
- Bromine (Br) concentration using an ion-exchange chromatograph. milli-molar
- pore water chemistry; sample::Rb concentration: ICP-MS [nM]
- Rubidium (Rb) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry; sample::Sr concentration: ICP-AES [µM]
- Strontium (Sr) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry; sample::Mo concentration: ICP-MS [nM]
- Molybdenum (Mo) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry; sample::Cs concentration: ICP-MS [nM]
- Cesium (Cs) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry; sample::Ba concentration: ICP-AES [µM]
- Barium (Ba) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry; sample::U concentration: ICP-MS [nM]
- Uranium (U) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry
-
Measurements for squeezed pore water samples.
- pore water chemistry::pmH: pH electrode, attached to titrator
- pmH on free hydrogen ion concentration scale using a pH electrode attached to titrator. dimensionless quantity
- pore water chemistry::alkalinity: titrator [mM]
- Alkalinity using a titrator. milli-molar
- pore water chemistry::alkalinity full result
- Full results of alkalinity measurement.
- bulk CNS analysis; sample, section
-
Measurements of carbon, nitrogen and sulfur content for bulk samples taken from
core sections.
- bulk CNS analysis; sample, section::inorganic carbon content: carbonate analyzer [wt%]
- Inorganic carbon content measured by using a carbonate analyzer. weight percentage
- bulk CNS analysis; sample, section::CaCO3 content: from inorganic carbon content [wt%]
- Calcium carbonate (CaCO3) content derived from inorganic carbon content. weight percentage
- bulk CNS analysis
-
Measurements of carbon, nitrogen and sulfur content for bulk samples.
- bulk CNS analysis::nitrogen content: EA, bulk [wt%]
- Nitrogen content by measuring bulk samples using a CHNS/O elemental analyzer. weight percentage
- bulk CNS analysis::total carbon content: EA, bulk [wt%]
- Total carbon content by measuring bulk samples using a CHNS/O elemental analyzer. weight percentage
- bulk CNS analysis::sulfur content: EA, bulk [wt%]
- Sulfur content by measuring bulk samples using a CHNS/O elemental analyzer. weight percentage
- bulk CNS analysis::measurement date-time: EA, bulk
- Date and time when measuring bulk samples using a CHNS/O elemental analyzer.
- downhole measurement
-
Measurements by using downhole tools.
- downhole measurement::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.