Hole C0002G, Expedition 332

Lineage

This URL provides the access to the most recent output from the database. The output is being overwritten as often as possible.

This data set was output from J-CORES database by using its complete Bulk Export function Version 1.9.9 from 2016-11-16T18:31:35Z till 2016-11-16T18:33:25Z. The specification of the outputs is available to be referred. Bulk Export gives a file bulk.csv with various attachment files (e.g. image files). Files bulk-something.csv are generated by picking some kinds of data from bulk.csv. Files something.zip consist of bulk-something.csv and related attachment files. Files bulk-something.csv are in character encoding UTF-8 with line ending characters CRLF. The database has a flexibility to store numerical/text values and attached files for user-defined parameters, which are output into User-Defined Parameter column group in bulk.csv.

Data file index

File Contents Length (bytes)
bulk-hole.csv Expedition, site and hole records 699
bulk-well-logging.csv Logging while drilling (LWD) and wire-line logging 6981914

Parameter definitions

The user-defined parameters are listed with their definitions as the followings.

arcVISION, well logging (1)
Well logging tool arcVISION (array resistivity compensated tool) by the first run at the hole during the expedition.
arcVISION, well logging (1)::attenuation conductivity 16 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::attenuation conductivity 16 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::attenuation conductivity 22 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::attenuation conductivity 22 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::attenuation conductivity 28 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::attenuation conductivity 28 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::attenuation conductivity 34 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::attenuation conductivity 34 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::attenuation conductivity 40 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::attenuation conductivity 40 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::attenuation resistivity 16 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::attenuation resistivity 16 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::attenuation resistivity 22 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::attenuation resistivity 22 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::attenuation resistivity 28 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::attenuation resistivity 28 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::attenuation resistivity 34 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::attenuation resistivity 34 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::attenuation resistivity 40 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::attenuation resistivity 40 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::gamma ray [gAPI]
api (American Petroleum Institute) gamma ray
arcVISION, well logging (1)::phase shift conductivity 16 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::phase shift conductivity 16 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::phase shift conductivity 22 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::phase shift conductivity 22 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::phase shift conductivity 28 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::phase shift conductivity 28 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::phase shift conductivity 34 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::phase shift conductivity 34 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::phase shift conductivity 40 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::phase shift conductivity 40 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (1)::phase shift resistivity 16 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::phase shift resistivity 16 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::phase shift resistivity 22 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::phase shift resistivity 22 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::phase shift resistivity 28 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::phase shift resistivity 28 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::phase shift resistivity 34 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::phase shift resistivity 34 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::phase shift resistivity 40 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (1)::phase shift resistivity 40 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)
Well logging tool arcVISION (array resistivity compensated tool) by the second run at the hole during the expedition.
arcVISION, well logging (2)::attenuation conductivity 16 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::attenuation conductivity 16 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::attenuation conductivity 22 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::attenuation conductivity 22 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::attenuation conductivity 28 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::attenuation conductivity 28 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::attenuation conductivity 34 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::attenuation conductivity 34 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::attenuation conductivity 40 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::attenuation conductivity 40 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::attenuation resistivity 16 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::attenuation resistivity 16 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::attenuation resistivity 22 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::attenuation resistivity 22 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::attenuation resistivity 28 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::attenuation resistivity 28 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::attenuation resistivity 34 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::attenuation resistivity 34 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::attenuation resistivity 40 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::attenuation resistivity 40 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::gamma ray [gAPI]
api (American Petroleum Institute) gamma ray
arcVISION, well logging (2)::phase shift conductivity 16 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::phase shift conductivity 16 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::phase shift conductivity 22 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::phase shift conductivity 22 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::phase shift conductivity 28 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::phase shift conductivity 28 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::phase shift conductivity 34 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::phase shift conductivity 34 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::phase shift conductivity 40 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::phase shift conductivity 40 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (2)::phase shift resistivity 16 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::phase shift resistivity 16 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::phase shift resistivity 22 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::phase shift resistivity 22 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::phase shift resistivity 28 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::phase shift resistivity 28 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::phase shift resistivity 34 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::phase shift resistivity 34 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::phase shift resistivity 40 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (2)::phase shift resistivity 40 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)
Well logging tool arcVISION (array resistivity compensated tool) by the third run at the hole during the expedition.
arcVISION, well logging (3)::attenuation resistivity 16 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::attenuation resistivity 16 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::attenuation resistivity 22 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::attenuation resistivity 22 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::attenuation resistivity 28 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::attenuation resistivity 28 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::attenuation resistivity 34 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::attenuation resistivity 34 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::attenuation resistivity 40 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::attenuation resistivity 40 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::gamma ray [gAPI]
api (American Petroleum Institute) gamma ray
arcVISION, well logging (3)::phase shift resistivity 16 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::phase shift resistivity 16 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::phase shift resistivity 22 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::phase shift resistivity 22 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::phase shift resistivity 28 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::phase shift resistivity 28 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::phase shift resistivity 34 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::phase shift resistivity 34 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::phase shift resistivity 40 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (3)::phase shift resistivity 40 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)
Well logging tool arcVISION (array resistivity compensated tool) by the fourth run at the hole during the expedition.
arcVISION, well logging (4)::attenuation conductivity 16 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::attenuation conductivity 16 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::attenuation conductivity 22 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::attenuation conductivity 22 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::attenuation conductivity 28 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::attenuation conductivity 28 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::attenuation conductivity 34 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::attenuation conductivity 34 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::attenuation conductivity 40 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::attenuation conductivity 40 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::attenuation resistivity 16 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::attenuation resistivity 16 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::attenuation resistivity 22 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::attenuation resistivity 22 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::attenuation resistivity 28 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::attenuation resistivity 28 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::attenuation resistivity 34 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::attenuation resistivity 34 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::attenuation resistivity 40 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::attenuation resistivity 40 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::gamma ray [gAPI]
api (American Petroleum Institute) gamma ray
arcVISION, well logging (4)::phase shift conductivity 16 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::phase shift conductivity 16 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::phase shift conductivity 22 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::phase shift conductivity 22 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::phase shift conductivity 28 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::phase shift conductivity 28 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::phase shift conductivity 34 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::phase shift conductivity 34 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::phase shift conductivity 40 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::phase shift conductivity 40 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (4)::phase shift resistivity 16 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::phase shift resistivity 16 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::phase shift resistivity 22 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::phase shift resistivity 22 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::phase shift resistivity 28 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::phase shift resistivity 28 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::phase shift resistivity 34 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::phase shift resistivity 34 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::phase shift resistivity 40 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (4)::phase shift resistivity 40 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)
Well logging tool arcVISION (array resistivity compensated tool) by the fifth run at the hole during the expedition.
arcVISION, well logging (5)::attenuation conductivity 16 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::attenuation conductivity 16 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::attenuation conductivity 22 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::attenuation conductivity 22 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::attenuation conductivity 28 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::attenuation conductivity 28 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::attenuation conductivity 34 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::attenuation conductivity 34 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::attenuation conductivity 40 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::attenuation conductivity 40 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::attenuation resistivity 16 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::attenuation resistivity 16 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::attenuation resistivity 22 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::attenuation resistivity 22 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::attenuation resistivity 28 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::attenuation resistivity 28 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::attenuation resistivity 34 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::attenuation resistivity 34 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::attenuation resistivity 40 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::attenuation resistivity 40 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::gamma ray [gAPI]
api (American Petroleum Institute) gamma ray
arcVISION, well logging (5)::phase shift conductivity 16 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::phase shift conductivity 16 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::phase shift conductivity 22 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::phase shift conductivity 22 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::phase shift conductivity 28 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::phase shift conductivity 28 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::phase shift conductivity 34 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::phase shift conductivity 34 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::phase shift conductivity 40 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::phase shift conductivity 40 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (5)::phase shift resistivity 16 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::phase shift resistivity 16 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::phase shift resistivity 22 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::phase shift resistivity 22 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::phase shift resistivity 28 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::phase shift resistivity 28 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::phase shift resistivity 34 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::phase shift resistivity 34 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::phase shift resistivity 40 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (5)::phase shift resistivity 40 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)
Well logging tool arcVISION (array resistivity compensated tool). The composite was the first one built at the hole during the expedition.
arcVISION, well logging (Composite 1)::attenuation conductivity 16 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::attenuation conductivity 16 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::attenuation conductivity 22 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::attenuation conductivity 22 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::attenuation conductivity 28 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::attenuation conductivity 28 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::attenuation conductivity 34 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::attenuation conductivity 34 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::attenuation conductivity 40 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::attenuation conductivity 40 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by attenuation mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::attenuation resistivity 16 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::attenuation resistivity 16 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::attenuation resistivity 22 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::attenuation resistivity 22 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::attenuation resistivity 28 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::attenuation resistivity 28 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::attenuation resistivity 34 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::attenuation resistivity 34 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::attenuation resistivity 40 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::attenuation resistivity 40 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by attenuation mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::gamma ray [gAPI]
api (American Petroleum Institute) gamma ray
arcVISION, well logging (Composite 1)::phase shift conductivity 16 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::phase shift conductivity 16 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::phase shift conductivity 22 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::phase shift conductivity 22 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::phase shift conductivity 28 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::phase shift conductivity 28 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::phase shift conductivity 34 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::phase shift conductivity 34 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::phase shift conductivity 40 inch spacing at 2 MHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::phase shift conductivity 40 inch spacing at 400 kHz, environmentally corrected [mS/m]
Conductivity measurement was done by phase shift mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. milli-Siemens per meter
arcVISION, well logging (Composite 1)::phase shift resistivity 16 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::phase shift resistivity 16 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 16 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::phase shift resistivity 22 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::phase shift resistivity 22 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 22 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::phase shift resistivity 28 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::phase shift resistivity 28 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 28 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::phase shift resistivity 34 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::phase shift resistivity 34 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 34 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::phase shift resistivity 40 inch spacing at 2 MHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 2 MHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter
arcVISION, well logging (Composite 1)::phase shift resistivity 40 inch spacing at 400 kHz, environmentally corrected [ohm m]
Resistivity measurement was done by phase shift mode with 400 kHz frequency and 40 inches spacing between a transmitter and receiver. Environment correction has been done. ohm by meter

See also