Hole C0024D, Expedition 358
Lineage
This URL provides the access to the most recent output from the database. The output is being overwritten as often as possible.
This data set was output from J-CORES database by using its complete Bulk Export function Version 1.9.9 from 2019-09-11T04:26:23Z till 2019-09-11T04:28:21Z.
The specification of the outputs is available to be referred.
Bulk Export gives a file bulk.csv
with various attachment files (e.g. image files).
Files bulk-something.csv
are generated
by picking some kinds of data from bulk.csv
.
Files something.zip
consist of
bulk-something.csv
and related attachment files.
Files bulk-something.csv
are in character encoding UTF-8
with line ending characters CRLF
.
The database has a flexibility to store numerical/text values and attached files for user-defined parameters,
which are output into User-Defined Parameter column group
in bulk.csv
.
Data file index
File | Contents | Length (bytes) |
---|---|---|
bulk-hole.csv | Expedition, site and hole records | 1054 |
bulk-core.csv | Core drilling and curatorial records | 4868 |
bulk-section.csv | Core section records | 21229 |
sample.zip | Records of ship and personal samples taken from core sections and miscellaneous materials | 18251 |
vcd.zip | Visual core descriptions (VCD) | 452900 |
microphoto.zip | Photo images of microscopy | 126132325 |
xray-ct-scanner.zip | X-ray CT scanned coronal images of core sections | 25002914 |
mscl.zip | Physical properties by Multi Sensor Core Logger(s) (MSCL) | 69680 |
split-section-image.zip | Images of split halves of core sections | 69417346 |
moisture-density.zip | Moisture and density (MAD) for discrete samples | 14939 |
thermal-conductivity.zip | Thermal conductivity for core sections | 991 |
bulk-electrical-conductivity.csv | Electrical conductivity for discrete samples | 15430 |
bulk-magnetic-susceptibility.csv | Magnetic susceptibility for discrete samples | 3970 |
bulk-magnetometer.csv | Magnetometry for split halves of core sections and discrete samples | 1403867 |
xrd.zip | XRD for bulk discrete samples | 790471 |
bulk-xrf.csv | XRF for bulk discrete samples | 8290 |
headspace-gas.zip | Headspace gas analyses | 1655 |
pore-water-chemistry.zip | Chemistry for pore water | 3958 |
bulk-cns-analysis.zip | Bulk CNS analyses for discrete samples | 2754 |
bulk-penetration-shear-strength.csv | Penetration and shear strength | 14512 |
downhole-measurement.zip | Downhole measurements | 8153380 |
Parameter definitions
The user-defined parameters are listed with their definitions as the followings.
- X-ray CT scanning
-
X-ray CT scanned images for core sections. The right-handed coordinate system is
applied to each core section as the followings. Y axis is from the working half
toward the archive half. Z axis is from the core bottom toward the top. (x, y,
z) = (0, 0, 0) at the center of the top of the core section.
- X-ray CT scanning::coronal image
- The cross section at the boundary of the working and archive halves of the core section, looking the archive half side. In other words, the x-z plane (y = 0), looking to the negative y. The image is created by compiling the series of axial images, at each of which z is a constant. The file is formatted in DICOM.
- X-ray CT scanning::top margin [pixels]
- Height of the margin at the top of the image. Not always integer. number of pixels in raster graphics
- X-ray CT scanning::bottom margin [pixels]
- Height of the margin at the bottom of the image. Not always integer. number of pixels in raster graphics
- X-ray CT scanning::each side margin [pixels]
- Width of the margin at each of the right and the left of the image. Not always integer. number of pixels in raster graphics
- X-ray CT scanning::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- split section image
-
Images for split core sections. At the top and the right there are no margins.
- split section image::line scanned image
- A surface image acquired by a line scan camera.
- split section image::bottom margin [pixels]
- Height of the margin at the bottom of the image. Not always integer. number of pixels in raster graphics
- split section image::left margin [pixels]
- Width of the margin at the left of the image. Not always integer. number of pixels in raster graphics
- split section image::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- VCD microscopic photography; smear slide
-
Smear slide photographs for visual core description (VCD).
- VCD microscopic photography; smear slide::photography object
- What was shot for the photograph.
- VCD microscopic photography; smear slide::polarizing microscopic image
- Image file acquired by using a polarizing microscope.
- VCD microscopic photography; smear slide::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- MSCL; section
-
Measurements for core sections by using a Multi Sensor Core Logger (MSCL).
- MSCL; section::section half
- Whether whole-round core sections or split halves of core sections and which side of split halves, for which the measurement is conducted. The values for this parameter have to be chosen from `whole-round', `archive', `working' and `either half'.
- MSCL; section::GRA density: horizontal sensor direction [g/cm3]
- Density calculated with Gamma Ray Attenuation (GRA) method. The sensor, a set of an RI source (137Cs) and a scintilation detector, is attached in the horizontal direction on the track of the Multi Sensor Core Logger (i.e., gamma ray beam passes through at the split point between working and archive halves). gram per cubic centi-meter
- MSCL; section::magnetic susceptibility: loop sensor, 80 mm (x0.00001 SI)
- Volume magnetic susceptibility in SI units by using a MS2C core logging sensor, Bartington Instruments Ltd. Loop internal diameter of the sensor is 80 mm. The values are derived by multiplying the actual values by 100000. dimensionless quantity
- MSCL; section::P-wave velocity: ARC transducer, 230 kHz [m/s]
- Measured P-wave velocity. The P-wave transducer is an oil filled acoustinc rolling contract (ARC) transducer. A set of the transmitter and a receiver, is attached in the horizontal direction on the track of the Multi Sensor Core Logger (i.e., P-wave passes through at the split point between working and archive halves). P-wave pulse which is an ultrasonic compressional pulse generated by a piezoelectric crystal is 230 kHz. meter per second
- MSCL; section::P-wave signal amplitude: ARC transducer, 230 kHz
- Measured P-wave signal amplitude. The P-wave transducer is an oil filled acoustinc rolling contract (ARC) transducer. A set of the transmitter and a receiver, is attached in the horizontal direction on the track of the Multi Sensor Core Logger (i.e., P-wave passes through at the split point between working and archive halves). P-wave pulse which is an ultrasonic compressional pulse generated by a piezoelectric crystal is 230 kHz. dimensionless quantity
- MSCL; section::electrical resistivity [ohm m]
- Measured electrical resistivity. ohm by meter
- MSCL; section::natural gamma radiation: detector set #1, 80 mm [CPS]
- Counts per seconds of detected gamma ray photons. This count is a total of four scintillation detectors. Each of the four detectors is combined with a multichannel analyser. They are attached in a cross shape on a central lead cube which is on the track of the Multi Sensor Core Logger. Serial number of the each detector is; the upper side (a detector at the direction of 12 o'clock from the view in the core movement direction) is 04L033, the right side (at 3 o'clock) is 04L028, the lower side (at 6 o'clock) is 04L034, and the left side (at 9 o'clock) is 04L041. The aperture of the central lead cube is 80 mm. counts per second
- thermal conductivity; section
-
Thermal conductivity measurements for core sections. Thermal conductivity is the
average value of those by iterative measurements.
- thermal conductivity; section::section half
- Whether whole-round core sections or split halves of core sections and which side of split halves, for which the measurement is conducted. The values for this parameter have to be chosen from `whole-round', `archive', `working' and `either half'.
- thermal conductivity; section::thermal conductivity [W/(m K)]
- Measured thermal conductivity value. watts per kelvin per meter
- thermal conductivity; section::standard deviation of thermal conductivity [W/(m K)]
- Standard deviation from iterative thermal conductivity measurements. watts per kelvin per meter
- thermal conductivity; section::measurement quality based on LET
- Measurement quality evaluation based on logarithm of the extreme time (LET) values of the best solution (TK04 User's Manual; TeKa, Berlin, Germany). LET information indicates the quality of the thermal conductivity measurement by TK04. According to a vendor's comment, "LET should at least reach values of 50 (even with difficult samples like sediments), better more than 100. If LET values are not higher than 4 when measuring sediments, this means that the contact between probe and sample is insufficient." If the highest LET value of the iterative measurements is 4 and over, the data is evaluated as "Qualified" and low quality measurement results (LET <4) are excluded from the average of thermal conductivity. In case the highest LET value of the iterative measurements is lower than 4, the data is evaluated as "Unqualified" and the average of all measurements is given as the thermal conductivity.
- thermal conductivity; section::number of iterative measurements
- How many iterative measurements are conducted for the measurement. dimensionless quantity
- thermal conductivity; section::thermal conductivity probe
- Type of the probe used for the thermal conductivity measurement.
- thermal conductivity; section::thermal conductivity probe serial number
- Serial number of the probe used for the thermal conductivity measurement.
- thermal conductivity; section::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- moisture and density
-
Moisture and density (MAD) measurements for bulk samples.
- moisture and density::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- moisture and density::beaker mass [g]
- Mass of beaker used for the measurement. gram
- moisture and density::beaker volume [cm3]
- Volume of beaker used for the measurement. cubic centi-meter
- moisture and density::wet sample beaker+sample mass [g]
- Mass of the wet sample with the beaker. gram
- moisture and density::wet bulk mass [g]
- Mass of the wet bulk sample, derived by subtracting the beaker mass from the measurement of the sample with the beaker. gram
- moisture and density::dry sample beaker+sample mass [g]
- Mass of the dry sample with the beaker. gram
- moisture and density::dry sample beaker+sample volume [cm3]
- Volume of the dry sample with the beaker. cubic centi-meter
- moisture and density::dry bulk mass [g]
- Mass of the dry bulk sample, derived by subtracting the beaker mass from the measurement of the sample with the beaker. gram
- moisture and density::pore water mass [g]
- Derived by (Mt - Md) / (1 - s), where Mt, wet bulk mass; Md, dry bulk mass; s, salinity, assumed to 0.035 M. gram
- moisture and density::pore water volume [cm3]
- Derived by Mpw / Dpw, where Mpw, pore water mass; Dpw, density, assumed to 1.024 g/cm3. cubic centi-meter
- moisture and density::solids volume: dry bulk - salt [cm3]
- Derived by subtraction of the salt volume from the dry bulk volume. cubic centi-meter
- moisture and density::wet bulk volume: solids + pore water [cm3]
- Derived as the sum of volumes of solids and pore water. cubic centi-meter
- moisture and density::dry bulk volume [cm3]
- Volume of the dry bulk sample, derived by subtracting the beaker volume from the measurement of the sample with the beaker. cubic centi-meter
- moisture and density::salt mass [g]
- Derived by (Mt - Md) s, where Mt, wet bulk mass; Md, dry bulk mass; s, salinity, assumed to 0.035. gram
- moisture and density::salt volume [cm3]
- Derived by Msalt / Dsalt, where Msalt, salt mass; Dsalt, salt density, assumed to 2.22 g/cm3. cubic centi-meter
- moisture and density::solids mass [g]
- Derived by subtraction of the salt mass from the dry bulk mass. gram
- moisture and density::water content wet
- Derived by Mpw / Mt, where Mpw, pore water mass; Mt, wet bulk mass. dimensionless quantity
- moisture and density::water content dry
- Derived by Mpw / Ms, where Mpw, pore water mass; Ms, solids mass. dimensionless quantity
- moisture and density::bulk density [g/cm3]
- Moisture and density analysis derives this by quotient of wet bulk mass by wet bulk volume. Well logging tool adnVISION may give this by another way. gram per cubic centi-meter
- moisture and density::dry density [g/cm3]
- Derived by Ms / Vt, where Ms, solids mass; Vt, wet bulk volume. gram per cubic centi-meter
- moisture and density::grain density [g/cm3]
- Derived by Ms / Vs, where Ms, solids mass; Vs, solids volume. gram per cubic centi-meter
- moisture and density::porosity
- Derived by Vpw / Vt, where Vpw, pore water volume; Vt, wet bulk volume. dimensionless quantity
- moisture and density::void ratio
- Derived by Vpw / Vs, where Vpw, pore water volume; Vs, solids volume. dimensionless quantity
- impedance analysis; section
-
Measurements by using an impedance analyzer for core sections. Electrical
impedance, resistivity and conductivity are at the frequency of the applied
alternating current. The frequency is determined by the waveform of each
measurement.
- impedance analysis; section::frequency of applied alternating current [kHz]
- Frequency of the applied alternating current. kilo-hertz
- impedance analysis; section::section half
- Whether whole-round core sections or split halves of core sections and which side of split halves, for which the measurement is conducted. The values for this parameter have to be chosen from `whole-round', `archive', `working' and `either half'.
- impedance analysis; section::electrical conductivity Y [S/m]
- Electrical conductivity along Y-axis. Siemens per meter
- impedance analysis; section::electrical resistivity Y [ohm m]
- Electrical resistivity along Y-axis. ohm by meter
- impedance analysis; section::electrical conductivity Z [S/m]
- Electrical conductivity along Z-axis. Siemens per meter
- impedance analysis; section::electrical resistivity Z [ohm m]
- Electrical resistivity along Z-axis. ohm by meter
- impedance analysis; section::room temperature [degree C]
- Room temperature measured by using a thermometer for the measurement. degree Celsius
- impedance analysis; section::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- Kappabridge
-
Kappabridge measurements for bulk samples.
- Kappabridge::magnetic susceptibility (SI)
- Volume magnetic susceptibility in SI units. dimensionless quantity
- superconducting rock magnetometer; section
-
Measurements by using a superconducting rock magnetometer for continuous halves
of core sections.
- superconducting rock magnetometer; section::alternating-field demagnetization level [mT]
- Level of applied alternating-field demagnetization. milli-tesla
- superconducting rock magnetometer; section::magnetic intensity [A/m]
- Intensity of magnetization per unit volume. This parameter is obtained by normalizing the magnetic moments by the sample volume for a discrete sample or by the effective sample volume for a continuous section half. ampere per meter
- superconducting rock magnetometer; section::magnetic inclination [degree]
- Angle of the magnetic dip from the horizontal plane. This value can be between -90=<, =<90 degree. -90 and 90 degrees indicate the direction toward -Z and +Z respectively in the ODP orientation system (Handbook for shipboard paleomagnetists; ODP Tech. Note, 34, 2007). degree
- superconducting rock magnetometer; section::magnetic declination [degree]
- Angle of the magnetic azimuth on the horizontal plane. This value can be between 0=<, <360 degree. 0, 90, and 180 degrees indicate the direction toward +X, +Y, and -X respectively in the ODP orientation system (Handbook for shipboard paleomagnetists; ODP Tech. Note, 34, 2007). degree
- superconducting rock magnetometer; section::section half
- Whether whole-round core sections or split halves of core sections and which side of split halves, for which the measurement is conducted. The values for this parameter have to be chosen from `whole-round', `archive', `working' and `either half'.
- superconducting rock magnetometer comment
-
Comments for superconducting rock magnetometer measurement for continuous halves
of core sections.
- superconducting rock magnetometer comment::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- superconducting rock magnetometer
-
Measurements by using a superconducting rock magnetometer for discrete sample.
Parameter of demagnetization or magnetization show the applied demagnetization
or magnetization before measurement. If demagnetization and magnetization values
described in same line in a data file, it means the demagnetization is done
after the magnetization.
- superconducting rock magnetometer::alternating-field demagnetization level [mT]
- Level of applied alternating-field demagnetization. milli-tesla
- superconducting rock magnetometer::magnetic intensity [A/m]
- Intensity of magnetization per unit volume. This parameter is obtained by normalizing the magnetic moments by the sample volume for a discrete sample or by the effective sample volume for a continuous section half. ampere per meter
- superconducting rock magnetometer::magnetic inclination [degree]
- Angle of the magnetic dip from the horizontal plane. This value can be between -90=<, =<90 degree. -90 and 90 degrees indicate the direction toward -Z and +Z respectively in the ODP orientation system (Handbook for shipboard paleomagnetists; ODP Tech. Note, 34, 2007). degree
- superconducting rock magnetometer::magnetic declination [degree]
- Angle of the magnetic azimuth on the horizontal plane. This value can be between 0=<, <360 degree. 0, 90, and 180 degrees indicate the direction toward +X, +Y, and -X respectively in the ODP orientation system (Handbook for shipboard paleomagnetists; ODP Tech. Note, 34, 2007). degree
- XRD
-
Measurements by using a X-ray diffractometer for a bulk powder sample mounted on
a glass plate.
- XRD::diffraction profile, UDF
- Measurement results of X-ray diffraction measurement. The file format is the Philips UDF (ASCII). The file is converted from the RD by using X'Pert High Score, PANalytical.
- XRD::diffraction profile, RD
- Measurement results of X-ray diffraction measurement. The file format is the Philips RD (binary).
- XRF
-
Measurements by using a X-ray fluorescence spectrometer for bulk samples.
- XRF::Na2O content [wt%]
- Content of sodium oxide. weight percentage
- XRF::MgO content [wt%]
- Content of magnesium oxide. weight percentage
- XRF::Al2O3 content [wt%]
- Content of aluminum oxide. weight percentage
- XRF::SiO2 content [wt%]
- Content of silicon dioxide. weight percentage
- XRF::P2O5 content [wt%]
- Content of phosphorus pentoxide. weight percentage
- XRF::K2O content [wt%]
- Content of potassium oxide. weight percentage
- XRF::CaO content [wt%]
- Content of calcium oxide. weight percentage
- XRF::TiO2 content [wt%]
- Content of titanium dioxide. weight percentage
- XRF::MnO content [wt%]
- Content of manganese oxide. weight percentage
- XRF::Fe2O3 content [wt%]
- Content of ferric oxide. weight percentage
- XRF::loss on ignition [wt%]
- Content of loss on ignition by weighing the amount of volatile substances such as constitution water or carbonates lost when samples are ignited with muffle furnace. weight percentage
- XRF::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- headspace gas analysis
-
Measurements for bulk samples by headspace gas analysis.
- headspace gas analysis::methane concentration: GC-FID [ppm]
- Methane concentration by using a gas chromatograph with a flame ionization detector. part per million
- headspace gas analysis::ethylene concentration: GC-FID [ppm]
- Ethylene concentration by using a gas chromatograph with a flame ionization detector. part per million
- headspace gas analysis::ethane concentration: GC-FID [ppm]
- Ethane concentration by using a gas chromatograph with a flame ionization detector. part per million
- headspace gas analysis::propylene concentration: GC-FID [ppm]
- Propylene concentration by using a gas chromatograph with a flame ionization detector. part per million
- headspace gas analysis::propane concentration: GC-FID [ppm]
- Propane concentration by using a gas chromatograph with a flame ionization detector. part per million
- headspace gas analysis::i-butane concentration: GC-FID [ppm]
- i-butane concentration by using a gas chromatograph with a flame ionization detector. part per million
- headspace gas analysis::n-butane concentration: GC-FID [ppm]
- n-butane concentration by using a gas chromatograph with a flame ionization detector. part per million
- pore water chemistry
-
Measurements for squeezed pore water samples.
- pore water chemistry::refractive index nD: refractometer
- Refractive index nD using a refractometer. dimensionless quantity
- pore water chemistry::salinity: refractometer [permil]
- Salinity using a refractometer. permillage
- pore water chemistry::pmH: pH electrode, attached to titrator
- pmH on free hydrogen ion concentration scale using a pH electrode attached to titrator. dimensionless quantity
- pore water chemistry::alkalinity: titrator [mM]
- Alkalinity using a titrator. milli-molar
- pore water chemistry::chlorinity: titrator, potentiometric titration [mM]
- Chlorinity using a titrator (potentiometric titration). milli-molar
- pore water chemistry::PO4 concentration: discrete analyzer, colorimetric analysis [µM]
- Phosphate (PO4) concentration using a discrete analyzer (colorimetric analysis). micro-molar
- pore water chemistry::NH4 concentration: discrete analyzer, colorimetric analysis [mM]
- Ammonium (NH4) concentration using a discrete analyzer (colorimetric analysis). milli-molar
- pore water chemistry::Br concentration: IC [mM]
- Bromine (Br) concentration using an ion-exchange chromatograph. milli-molar
- pore water chemistry::SO4 concentration: IC [mM]
- Sulfate (SO4) concentration using an ion-exchange chromatograph. milli-molar
- pore water chemistry::Na concentration: IC [mM]
- Sodium (Na) concentration using an ion-exchange chromatograph. milli-molar
- pore water chemistry::K concentration: IC [mM]
- Potassium (K) concentration using an ion-exchange chromatograph. milli-molar
- pore water chemistry::Mg concentration: IC [mM]
- Magnesium (Mg) concentration using an ion-exchange chromatograph. milli-molar
- pore water chemistry::Ca concentration: IC [mM]
- Calcium (Ca) concentration using an ion-exchange chromatograph. milli-molar
- pore water chemistry::B concentration: ICP-AES [µM]
- Boron (B) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry::Ba concentration: ICP-AES [µM]
- Barium (Ba) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry::Fe concentration: ICP-AES [µM]
- Iron (Fe) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry::Li concentration: ICP-AES [µM]
- Lithium (Li) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry::Mn concentration: ICP-AES [µM]
- Manganese (Mn) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry::Si concentration: ICP-AES [µM]
- Silicon (Si) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry::Sr concentration: ICP-AES [µM]
- Strontium (Sr) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- pore water chemistry::V concentration: ICP-MS [nM]
- Vanadium (V) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry::Cu concentration: ICP-MS [nM]
- Copper (Cu) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry::Zn concentration: ICP-MS [nM]
- Zinc (Zn) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry::As concentration: ICP-MS [nM]
- Arsenic (As) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry::Rb concentration: ICP-MS [nM]
- Rubidium (Rb) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry::Mo concentration: ICP-MS [nM]
- Molybdenum (Mo) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry::Cs concentration: ICP-MS [nM]
- Cesium (Cs) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry::Pb concentration: ICP-MS [nM]
- Lead (Pb) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry::U concentration: ICP-MS [nM]
- Uranium (U) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- pore water chemistry::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- bulk CNS analysis
-
Measurements of carbon, nitrogen and sulfur content for bulk samples.
- bulk CNS analysis::inorganic carbon content: carbonate analyzer [wt%]
- Inorganic carbon content measured by using a carbonate analyzer. weight percentage
- bulk CNS analysis::CaCO3 content: from inorganic carbon content [wt%]
- Calcium carbonate (CaCO3) content derived from inorganic carbon content. weight percentage
- bulk CNS analysis::nitrogen content: EA, bulk [wt%]
- Nitrogen content by measuring bulk samples using a CHNS/O elemental analyzer. weight percentage
- bulk CNS analysis::total carbon content: EA, bulk [wt%]
- Total carbon content by measuring bulk samples using a CHNS/O elemental analyzer. weight percentage
- bulk CNS analysis::sulfur content: EA, bulk [wt%]
- Sulfur content by measuring bulk samples using a CHNS/O elemental analyzer. weight percentage
- bulk CNS analysis::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- penetration strength; section
-
Penetration strength measured by using a penetrometer for core sections.
- penetration strength; section::section half
- Whether whole-round core sections or split halves of core sections and which side of split halves, for which the measurement is conducted. The values for this parameter have to be chosen from `whole-round', `archive', `working' and `either half'.
- penetration strength; section::penetration strength: penetrometer [kPa]
- Penetration strength measured by using a penetrometer, whose measurement range is 0--294 kPa. kilo-pascal
- penetration strength; section::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- shear strength; section
-
Shear strength measured by using a vane shear apparatus for core sections.
- shear strength; section::section half
- Whether whole-round core sections or split halves of core sections and which side of split halves, for which the measurement is conducted. The values for this parameter have to be chosen from `whole-round', `archive', `working' and `either half'.
- shear strength; section::shear strength: vane shear apparatus [kPa]
- Shear strength measured by using a vane shear apparatus, whose measurement range is 12--180 kPa. kilo-pascal
- shear strength; section::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- downhole measurement
-
Measurements by using downhole tools.
- downhole measurement::formation temperature: APCT3 [degree C]
- Formation temperature measured by using a downhole tool APCT3. degree Celsius
- downhole measurement::APCT3 result
- Measurement results of a downhole tool APCT3.
- downhole measurement::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.