Hole C0010A, Expedition 365
Lineage
This URL provides the access to the most recent output from the database. The output is being overwritten as often as possible.
This data set was output from J-CORES database by using its complete Bulk Export function Version 1.9.9 from 2018-01-23T01:14:46Z till 2018-01-23T01:14:59Z.
The specification of the outputs is available to be referred.
Bulk Export gives a file bulk.csv
with various attachment files (e.g. image files).
Files bulk-something.csv
are generated
by picking some kinds of data from bulk.csv
.
Files something.zip
consist of
bulk-something.csv
and related attachment files.
Files bulk-something.csv
are in character encoding UTF-8
with line ending characters CRLF
.
The database has a flexibility to store numerical/text values and attached files for user-defined parameters,
which are output into User-Defined Parameter column group
in bulk.csv
.
Data file index
File | Contents | Length (bytes) |
---|---|---|
bulk-hole.csv | Expedition, site and hole records | 762 |
bulk-miscellaneous-material.csv | Records of materials recovered from holes excepting cores | 1282 |
sample.zip | Records of ship and personal samples taken from core sections and miscellaneous materials | 5649 |
bulk-other-liquid-chemistry.csv | Chemistry for other kinds of liquid | 18612 |
bulk-other-gas.csv | Gas analyses for other kinds of samples | 1612 |
Parameter definitions
The user-defined parameters are listed with their definitions as the followings.
- osmo liquid chemistry
-
Measurements for liquid samples collected by using Osmotic sampler.
- osmo liquid chemistry::refractive index nD: refractometer
- Refractive index nD using a refractometer. dimensionless quantity
- osmo liquid chemistry::salinity: refractometer [permil]
- Salinity using a refractometer. permillage
- osmo liquid chemistry::pmH: pH electrode, attached to titrator
- pmH on free hydrogen ion concentration scale using a pH electrode attached to titrator. dimensionless quantity
- osmo liquid chemistry::alkalinity: titrator [mM]
- Alkalinity using a titrator. milli-molar
- osmo liquid chemistry::chlorinity: titrator, potentiometric titration [mM]
- Chlorinity using a titrator (potentiometric titration). milli-molar
- osmo liquid chemistry::NO2 concentration: IC [mM]
- Nitrite (NO2) concentration using an ion-exchange chromatograph. milli-molar
- osmo liquid chemistry::Br concentration: IC [mM]
- Bromine (Br) concentration using an ion-exchange chromatograph. milli-molar
- osmo liquid chemistry::NO3 concentration: IC [mM]
- Nitrate (NO3) concentration using an ion-exchange chromatograph. milli-molar
- osmo liquid chemistry::SO4 concentration: IC [mM]
- Sulfate (SO4) concentration using an ion-exchange chromatograph. milli-molar
- osmo liquid chemistry::Na concentration: IC [mM]
- Sodium (Na) concentration using an ion-exchange chromatograph. milli-molar
- osmo liquid chemistry::K concentration: IC [mM]
- Potassium (K) concentration using an ion-exchange chromatograph. milli-molar
- osmo liquid chemistry::Mg concentration: IC [mM]
- Magnesium (Mg) concentration using an ion-exchange chromatograph. milli-molar
- osmo liquid chemistry::Ca concentration: IC [mM]
- Calcium (Ca) concentration using an ion-exchange chromatograph. milli-molar
- osmo liquid chemistry::B concentration: ICP-AES [µM]
- Boron (B) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- osmo liquid chemistry::Ba concentration: ICP-AES [µM]
- Barium (Ba) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- osmo liquid chemistry::Fe concentration: ICP-AES [µM]
- Iron (Fe) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- osmo liquid chemistry::Li concentration: ICP-AES [µM]
- Lithium (Li) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- osmo liquid chemistry::Mn concentration: ICP-AES [µM]
- Manganese (Mn) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- osmo liquid chemistry::Si concentration: ICP-AES [µM]
- Silicon (Si) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- osmo liquid chemistry::Sr concentration: ICP-AES [µM]
- Strontium (Sr) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
- osmo liquid chemistry::V concentration: ICP-MS [nM]
- Vanadium (V) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- osmo liquid chemistry::Cu concentration: ICP-MS [nM]
- Copper (Cu) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- osmo liquid chemistry::Rb concentration: ICP-MS [nM]
- Rubidium (Rb) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- osmo liquid chemistry::Mo concentration: ICP-MS [nM]
- Molybdenum (Mo) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- osmo liquid chemistry::Cs concentration: ICP-MS [nM]
- Cesium (Cs) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- osmo liquid chemistry::Pb concentration: ICP-MS [nM]
- Lead (Pb) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- osmo liquid chemistry::U concentration: ICP-MS [nM]
- Uranium (U) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- osmo liquid chemistry::Y concentration: ICP-MS [nM]
- Yttrium (Y) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- osmo liquid chemistry::Co concentration: ICP-MS [nM]
- Cobalt (Co) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- osmo liquid chemistry::Cd concentration: ICP-MS [nM]
- Cadmium (Cd) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- osmo liquid chemistry::Cr concentration: ICP-MS [nM]
- Chromium (Cr) concentration using an inductively coupled plasma mass spectrometer. nano-molar
- osmo liquid chemistry::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
- osmo gas analysis
-
Measurements for gas samples from coiled tube collected by using Osmotic
sampler.
- osmo gas analysis::methane concentration: GC-FID [ppm]
- Methane concentration by using a gas chromatograph with a flame ionization detector. part per million
- osmo gas analysis::ethylene concentration: GC-FID [ppm]
- Ethylene concentration by using a gas chromatograph with a flame ionization detector. part per million
- osmo gas analysis::ethane concentration: GC-FID [ppm]
- Ethane concentration by using a gas chromatograph with a flame ionization detector. part per million
- osmo gas analysis::propylene concentration: GC-FID [ppm]
- Propylene concentration by using a gas chromatograph with a flame ionization detector. part per million
- osmo gas analysis::propane concentration: GC-FID [ppm]
- Propane concentration by using a gas chromatograph with a flame ionization detector. part per million
- osmo gas analysis::i-butane concentration: GC-FID [ppm]
- i-butane concentration by using a gas chromatograph with a flame ionization detector. part per million
- osmo gas analysis::n-butane concentration: GC-FID [ppm]
- n-butane concentration by using a gas chromatograph with a flame ionization detector. part per million
- osmo gas analysis::comment on measurement
- Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.