Table 1: Data sampling information
There are two types of surface buoy; m-TRITON type and K-TRITON type. The hights of the meteorological sensors installed on these buoy are different. The hights of K-TRITON type is 0.1m higher than m-TRITON type.

  Measurement Sampling Interval Height (m-TRITON type) / Depth
Meteorological Sensors
Wind Speed / Direction
10 min 3.1 m height
Air Temperature
10 min 2.3 m height
Relative Humidity
10 min 2.3 m height
Barometric Pressure
10 min 2.2 m height
Shortwave Radiation
10 min 2.9 m height
Longwave Radiation
10 min 2.9 m height
Precipitation
10 min 3.0 m height
Oceanic Sensors
Current Velocity
20 min Installed downward-looking at 1 m depth with 30 bins of 4 m length
Water Temperature
10 min 1, 10, 20, 40, 60, 80, 90, 100, 110, 120, 150, 180, 200, 300 m depth
Conductivity
Pressure
Dissolved Oxygen (DO) Concentration
10 min 80, 100, 150 m depth
CO2(Option)
1 h 1 m depth
pH(Option)
1 h 1 m depth


Table 2: Information of sensors installed on the PhBuoy

  Measurement Model Manufacturer Accuracy Resolution
Meteorological Sensors
Wind Speed
Y85000 JAMSTEC ±2 ~ 3 % 0.1 m/s
Wind Direction
±1 ° 1 °
Air Temperature
MP103A Rotronic ±0.05 ℃ 0.01℃
Relative Humidity
±0.3 % 0.01 %
Barometric Pressure
RPS 8100 GE ±0.1hPa N/A
Shortwave Radiation
Eppley Precision Spectral Pyranometer (EPSP) ASIMET(JAMSTEC) ±2 W/m2 0.1 W/m2
Longwave Radiation
Eppley Precision Infrared Radiometer (EPIR)
ASIMET
±2 W/m2 0.1 W/m2
Precipitation
50202/50203 R.M. Young ±1 mm 0.1 mm
Oceanic Sensors
Current Velocity
300 kHz Workhorse Sentinel ADCP Teledyne RD Instruments ±0.5 cm/s 0.1 cm/s
Water Temperature
SBE 37-IM MicroCAT CT/CTD Sea-Bird Electronics ±0.002 ℃ 0.0001℃
Conductivity
±0.0003 S/m 0.00001 S/m
Pressure
±0.1 % FSR 0.002 % FSR
Dissolved Oxygen (DO) Concentration
RINKO Ⅰ AROUSB JFE Advantech ±0.01~0.04 % 2 % FSR
CO2(Option)
pH-CO2 hybrid sensor HCST JAMSTEC    
pH(Option)
   





Contact:
Dr. Iwao Ueki
E-mail uekii [at] jamstec.go.jp