Table 1: Data sampling information
|
| There are two types of surface buoy; m-TRITON type and K-TRITON type. The hights of the meteorological sensors installed on these buoy are different. The hights of K-TRITON type is 0.1m higher than m-TRITON type. |
| Measurement | Sampling Interval | Height (m-TRITON type) / Depth | |
| Meteorological Sensors | Wind Speed / Direction |
10 min | 3.1 m height |
Air Temperature |
10 min | 2.3 m height | |
Relative Humidity |
10 min | 2.3 m height | |
Barometric Pressure |
10 min | 2.2 m height | |
Shortwave Radiation |
10 min | 2.9 m height | |
Longwave Radiation |
10 min | 2.9 m height | |
Precipitation |
10 min | 3.0 m height | |
| Oceanic Sensors | Current Velocity |
20 min | Installed downward-looking at 1 m depth with 30 bins of 4 m length |
Water Temperature |
10 min | 1, 10, 20, 40, 60, 80, 90, 100, 110, 120, 150, 180, 200, 300 m depth | |
Conductivity |
|||
Pressure |
|||
Dissolved Oxygen (DO) Concentration |
10 min | 80, 100, 150 m depth | |
CO2(Option) |
1 h | 1 m depth | |
pH(Option) |
1 h | 1 m depth |
Table 2: Information of sensors installed on the PhBuoy
| Measurement | Model | Manufacturer | Accuracy | Resolution | |
| Meteorological Sensors | Wind Speed |
Y85000 | JAMSTEC | ±2 ~ 3 % | 0.1 m/s |
Wind Direction |
±1 ° | 1 ° | |||
Air Temperature |
MP103A | Rotronic | ±0.05 ℃ | 0.01℃ | |
Relative Humidity |
±0.3 % | 0.01 % | |||
Barometric Pressure |
RPS 8100 | GE | ±0.1hPa | N/A | |
Shortwave Radiation |
Eppley Precision Spectral Pyranometer (EPSP) | ASIMET(JAMSTEC) | ±2 W/m2 | 0.1 W/m2 | |
Longwave Radiation |
Eppley Precision Infrared Radiometer (EPIR) | ASIMET |
±2 W/m2 | 0.1 W/m2 | |
Precipitation |
50202/50203 | R.M. Young | ±1 mm | 0.1 mm | |
| Oceanic Sensors | Current Velocity |
300 kHz Workhorse Sentinel ADCP | Teledyne RD Instruments | ±0.5 cm/s | 0.1 cm/s |
Water Temperature |
SBE 37-IM MicroCAT CT/CTD | Sea-Bird Electronics | ±0.002 ℃ | 0.0001℃ | |
Conductivity |
±0.0003 S/m | 0.00001 S/m | |||
Pressure |
±0.1 % FSR | 0.002 % FSR | |||
Dissolved Oxygen (DO) Concentration |
RINKO Ⅰ AROUSB | JFE Advantech | ±0.01~0.04 % | 2 % FSR | |
CO2(Option) |
pH-CO2 hybrid sensor HCST | JAMSTEC | |||
pH(Option) |
Contact: