Hole C0020A Well Logging, Expedition 337
WL (Run1 [TLD, CNL, MCFL, HNGS, SP and HRLA], Run2 [FMI, DSI, EMS], Run3 [CMR], Run4 [MDT] and Run5 [VSI]) for Hole 337-C0020A
Information
The well log is a record of one or more physical measurements as a function of depth in a borehole (From “Encyclopedic Dictionary of Applied Geophysics”). To measure the various values at once, one or more sondes comprise a tool string. Formation evaluation, lithological classification, and other geological interpretations are carried out from the logging curves or crossplots.
Digital Log Data and Graphics Format
- DLIS(Digital Log Information Standard) is one of most popular formats. DLIS is binary format and keeps acquisition and processing information in it. Most of logging service third parties provide data as DLIS files.
- LAS(Log ASCII Standard) is ASCII format composed of header and numerical data. Not only logging software but also any text editor or MS-Excel allow you to view and edit it. There are ver.2 and 3 (Data loader of Epos 3 by Paradigm accepts only ver.2 as is Jan/2009). Note that some acquisition and processing information are lost, when DLIS is converted to LAS.
- LIS(Log Information Standard) is one of most popular formats.(DLIS is more popular than LIS today)
- PDS is Schlumberger's graphic format. Schlumbeger's digital log field print and GeoFrame output are provided as PDS files. PDS has advantage of small file size and high resolution, but requires special software such as GeoFrame or BlueView to view and handle PDS files.
Data Index
See also data in the database for the same hole to refer related information.
Type | File (length in bytes) | Remark | ||
---|---|---|---|---|
ORIGINAL | DATA | Original TLD_MCFL_CNL_HNGS_HRLA (DLIS) | 337_C0020A_Run1_MAIN_TLD_MCFL_CNL_HNGS_HRLA.DLIS.zip (23820793) | Run 1 Main |
ORIGINAL | DATA | Original TLD_MCFL_CNL_HNGS_HRLA (DLIS) | 337_C0020A_Run1_REPEAT_TLD_MCFL_CNL_HNGS_HRLA.DLIS.zip (2440256) | Run 1 Repeat |
ORIGINAL | DATA | Original GR cased hole (DLIS) | 337_C0020A_Run1_GR_CASING.DLIS.zip (12267294) | Run 1 GR in cased hole |
ORIGINAL | DATA | Original FMI_DSI_EMS (DLIS) | 337_C0020A_Run2_MAIN_FMI_DSI_EMS.DLIS.zip (416809378) | Run 2 Main |
ORIGINAL | DATA | Original FMI_DSI_EMS (DLIS) | 337_C0020A_Run2_REPEAT_FMI_DSI_EMS.DLIS.zip (57343358) | Run 2 Repeat |
ORIGINAL | DATA | Original DSI cased hole (DLIS) | 337_C0020A_Run2_sonic_in_casing_FMI_DSI_EMS.DLIS.zip (16449312) | Run 2 DSI in cased hole |
ORIGINAL | DATA | Original CMR (DLIS) | 337_C0020A_Run3_MAIN_CMR.DLIS.zip (65255972) | Run 3 Main |
ORIGINAL | DATA | Original CMR (DLIS) | 337_C0020A_Run3_REPEAT_CMR.DLIS.zip (7402559) | Run 3 Repeat |
ORIGINAL | DATA | Original MDT (DLIS) | 337_C0020A_Run4_MDT_XLD_pretest_DLIS.zip (33128482) | Run 4 MDT XLD pretest |
ORIGINAL | DATA | Original MDT (LAS) | 337_C0020A_Run4_MDT_XLD_pretest_LAS.zip (264102) | Run 4 MDT XLD pretest Quartz Gauge Temperature and Pressure |
ORIGINAL | PLOTS | Original MDT (JPEG) | 337_C0020A_Run4_MDT_XLD_pretest_plot.zip (7755746) | Run 4 MDT XLD pretest |
ORIGINAL | DATA | Original MDT (DLIS) | 337_C0020A_Run4_MDT_QuickSilver_pretest_DLIS.zip (26714243) | Run 4 MDT QuickSilver pretest |
ORIGINAL | DATA | Original MDT (LAS) | 337_C0020A_Run4_MDT_QuickSilver_pretest_LAS.zip (225664) | Run 4 MDT QuickSilver pretest Quartz Gauge Temperature and Pressure |
ORIGINAL | PLOTS | Original MDT (JPEG) | 337_C0020A_Run4_MDT_QuickSilver_pretest_plot.zip (6060069) | Run 4 MDT QuickSilver pretest |
ORIGINAL | DATA | Original MDT (DLIS) | 337_C0020A_Run4_MDT_QuickSilver_Sampling_DLIS.zip (25144241) | Run 4 MDT QuickSilver sampling |
ORIGINAL | DATA | Original MDT (LAS) | 337_C0020A_Run4_MDT_QuickSilver_Sampling_LAS.zip (455233) | Run 4 MDT QuickSilver sampling IFA |
ORIGINAL | DATA | Original VSI (xls) | 337_C0020A_Run5_Checkshot_table.xls (52224) | Run 5 VSP checkshot |
ORIGINAL | DATA | Original VSI (SEGY) | 337_C0020A_Run5_VSI_SEGY.zip (86867422) | Run 5 VSP raw waveforms |
ORIGINAL | DOCUMENTS | Schlumberger Report (PDF) | 337_C0020A_Run4_MDT_XLD_pretest_report.pdf (650029) | Run 4 MDT XLD pretest report |
ORIGINAL | DOCUMENTS | Schlumberger Report (PDF) | 337_C0020A_Run4_MDT_QuickSilver_pretest_report.pdf (617192) | Run 4 MDT QuickSilver pretest report |
ORIGINAL | DOCUMENTS | Schlumberger Report (PDF) | 337_C0020A_Run4_MDT_QuickSilver_Sampling_report.pdf (1690606) | Run 4 MDT QuickSilver Sampling report |
ORIGINAL | DOCUMENTS | Schlumberger Report (PDF) | 337_C0020A-Run5_ZVSP_report.pdf (3586173) | Run 5 ZVSP report |
ORIGINAL | PLOTS | "Field Plot Combined Composite (1/200) (PDS, PDF)" | 337_C0020A_Run1_Combined_Composite.zip (2106996) | Run 1 Composite Main & pepeat |
ORIGINAL | PLOTS | "Field Plot GR (1/200) (PDS, PDF)" | 337_C0020A_Run1_Combined_GR.zip (701693) | Run 1 GR Main & pepeat & cased hole |
ORIGINAL | PLOTS | "Field Plot HNGS (1/200) (PDS, PDF)" | 337_C0020A_Run1_Combined_HNGS.zip (865633) | Run 1 HNGS Main & pepeat |
ORIGINAL | PLOTS | "Field Plot FMI (1/200) (PDS, PDF)" | 337_C0020A_Run2_Combined_FMI.zip (92222644) | Run 2 FMI Main & pepeat |
ORIGINAL | PLOTS | "Field Plot DSI (1/200) (PDS, PDF)" | 337_C0020A_Run2_Combined_DSI.zip (592965) | Run 2 DSI Main & pepeat & cased hole |
ORIGINAL | PLOTS | "Field Plot EMS (1/200) (PDS, PDF)" | 337_C0020A_Run2_Combined_EMS.zip (652026) | Run 2 EMS Main & pepeat |
ORIGINAL | PLOTS | "Field Plot CMR (1/200) (PDS, PDF)" | 337_C0020A_Run3_Combined_CMR.zip (967906) | Run 3 CMR Main & pepeat |
PROCESSED | DATA | Processed TLD_MCFL_CNL_HNGS_HRLA (DLIS) | 337-C0020A_Run1_TLD_MCFL_CNL_HRLA_proc.dlis (3603292) | Run 1 Main |
PROCESSED | DATA | Processed GR cased hole (DLIS) | 337-C0020A_Run1_GR_CASING_proc.dlis (128536) | Run 1 GR in cased hole |
PROCESSED | DATA | Processed FMI_DSI_EMS (DLIS) | 337-C0020A_Run2_FMI_DSI_EMS_CAL_proc.dlis (3340148) | Run 2 Main |
PROCESSED | DATA | Processed DSI cased hole (DLIS) | 337-C0020A_Run2_DSI_CASING_proc.dlis (49376) | Run 2 DSI in cased hole |
PROCESSED | DATA | Processed CMR (DLIS) | 337-C0020A_Run3_CMR_proc.dlis (1060116) | Run 3 Main |
PROCESSED | DATA | Processed VSP | 337-C0020A_Run5_VSP_results.zip (145004182) | Run 5 VSP |
PROCESSED | DOCUMENTS | Processing note (PFD) | 337-C0020A_data_processing_note.pdf (112120) | Standard processing note |
PROCESSED | PLOTS | "FMI Images 1240-1350mWMSF (1:100/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic100_1240to1350m.zip (25299380) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1350-1500mWMSF (1:100/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic100_1350to1500m.zip (33427358) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1500-1650mWMSF (1:100/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic100_1500to1650m.zip (32310687) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1650-1800mWMSF (1:100/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic100_1650to1800m.zip (31541589) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1800-1950mWMSF (1:100/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic100_1800to1950m.zip (30615010) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1950-2100mWMSF (1:100/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic100_1950to2100m.zip (30571463) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 2100-2250mWMSF (1:100/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic100_2100to2250m.zip (32508005) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 2250-2400mWMSF (1:100/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic100_2250to2400m.zip (31285000) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 2400-2460mWMSF (1:100/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic100_2400to2460m.zip (12734488) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1240-1350mWMSF (1:20/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic20_1240to1350m.zip (92679471) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1350-1500mWMSF (1:20/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic20_1350to1500m.zip (125832810) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1500-1650mWMSF (1:20/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic20_1500to1650m.zip (122773265) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1650-1800mWMSF (1:20/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic20_1650to1800m.zip (119192799) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1800-1950mWMSF (1:20/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic20_1800to1950m.zip (114674525) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1950-2200mWMSF (1:20/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic20_1950to2100m.zip (117411401) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 2100-2250mWMSF (1:20/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic20_2100to2250m.zip (125380380) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 2250-2400mWMSF (1:20/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic20_2250to2400m.zip (120364782) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 2400-2460mWMSF (1:20/Dynamic/PDS, PDF, TIFF)" | 337-C0020A_FMI_Dynamic20_2400to2460m.zip (59804805) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1240-1350mWMSF (1:100/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static100_1240to1350m.zip (13994869) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1350-1500mWMSF (1:100/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static100_1350to1500m.zip (24085725) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1500-1650mWMSF (1:100/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static100_1500to1650m.zip (24870534) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1650-1800mWMSF (1:100/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static100_1650to1800m.zip (23322170) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1800-1950mWMSF (1:100/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static100_1800to1950m.zip (21597552) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1950-2100mWMSF (1:100/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static100_1950to2100m.zip (19979658) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 2100-2250mWMSF (1:100/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static100_2100to2250m.zip (19975422) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 2250-2400mWMSF (1:100/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static100_2250to2400m.zip (23138633) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 2400-2460mWMSF (1:100/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static100_2400to2460m.zip (9455100) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1240-1350mWMSF (1:20/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static20_1240to1350m.zip (52699723) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1350-1500mWMSF (1:20/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static20_1350to1500m.zip (91924050) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1500-1650mWMSF (1:20/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static20_1500to1650m.zip (95701486) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1650-1800mWMSF (1:20/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static20_1650to1800m.zip (89034759) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1800-1950mWMSF (1:20/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static20_1800to1950m.zip (82733654) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 1950-2200mWMSF (1:20/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static20_1950to2100m.zip (78192304) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 2100-2250mWMSF (1:20/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static20_2100to2250m.zip (75831053) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 2250-2400mWMSF (1:20/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static20_2250to2400m.zip (89518682) | Run 2 FMI Image |
PROCESSED | PLOTS | "FMI Images 2400-2460mWMSF (1:20/Static/PDS, PDF, TIFF)" | 337-C0020A_FMI_Static20_2400to2460m.zip (36157221) | Run 2 FMI Image |
PROCESSED | PLOTS | "DSI Finalize (1:200/PDS,PDF)" | 337-C0020A_Run2_DSI_Finalize_200.zip (689062) | Run 2 FMI_DSI_EMS |
PROCESSED | PLOTS | "DSI Finalize (1:500/PDS,PDF)" | 337-C0020A_Run2_DSI_Finalize_500.zip (594874) | Run 2 FMI_DSI_EMS |
PROCESSED | PLOTS | "DSI Finalize in cased hole (1:200/PDS,PDF)" | 337-C0020A_Run2_DSI_Finalize_cased_200.zip (77164) | Run 2 FMI_DSI_EMS |
PROCESSED | PLOTS | "DSI Finalize in cased hole (1:500/PDS,PDF)" | 337-C0020A_Run2_DSI_Finalize_cased_500.zip (72290) | Run 2 FMI_DSI_EMS |
PROCESSED | PLOTS | "CMR (1:200/PDS,PDF)" | 337-C0020A_Run3_CMR_200.zip (2503538) | Run 3 CMR |
PROCESSED | PLOTS | "CMR (1:500/PDS,PDF)" | 337-C0020A_Run3_CMR_500.zip (2718605) | Run 3 CMR |